1-4
TO THE INSTALLER
Model C302
To the Installer
1
Initial Freezing Cylinder Cleaning
Due to the types of products used in FCB machines, it is
imperative that the freezing cylinder and the inlet tube be
thoroughly brush-cleaned, rinsed, and sanitized before
running any product.
Prepare a cleaning solution, using 2 oz. of liquid
detergent in 2 gal. of warm water. Using this solution,
brush-clean the freezing cylinder and the inlet tube.
Rinse the freezing cylinder and the inlet tube with clean
water. Sanitize, using the sanitizing procedures outlined
in this Operator Manual, starting on page 6-5.
Refrigerant
CAUTION!
This equipment contains
fluorinated greenhouse gases (F-Gas) to provide
refrigeration using a hermetically sealed circuit or within
foam insulation. This unit's type of gas, quantity, Global
Warming Potential (GWP) and CO2 tonnes equivalent
information is recorded on the unit's data-label. The
refrigerant used is generally considered non-toxic and
non-flammable. However any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion
CAUTION!
Use only approved refrigerant
listed on the unit's data-label or authorized through a
manufacturer's technical bulletin. The use of any other
refrigerant may expose users and operators to
unexpected safety hazards.
WARNING!
Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush them immediately with cold water. If burns are
severe, apply ice packs and contact a physician
immediately.
NOTICE!
Taylor reminds technicians to be
aware of and in compliance with local government laws
regarding refrigerant recovery, recycling, and reclaiming
systems. For information regarding applicable local laws,
please contact your local authorized Taylor distributor.
IMPORTANT!
Refrigerants and their
associated lubricants may be extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
!
!
Summary of Contents for C302
Page 10: ...2 2 TO THE OPERATOR Model C302 To the Operator 2 Notes...
Page 14: ...3 4 SAFETY Model C302 Safety 3 Notes...
Page 40: ...7 2 OPERATOR CHECKLIST Model C302 Operator Checklist 7 Notes...
Page 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 Parts Replacement Schedule 9 Notes...
Page 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C302 Limited Warranty on Equipment 10 Notes...
Page 52: ...11 4 LIMITED WARRANTY ON PARTS Model C302 Limited Warranty on Parts 11 Notes...