OPERATING PROCEDURES
6-11
Model C302
Operating Procedures
6
7. Repeat step 1 through step 6 for the other side of the
machine.
Cleaning
Note:
The following instructions are for one pair of
freezing cylinders under an LCD.
1. Prepare 2 gal. (7.6 L) of an approved cleaning
solution (examples: Kay-5
®
or Stera- Sheen
®
). Use
warm water and follow the manufacturer's
specifications.
Important!
Make sure the cleaner is completely
dissolved.
2. Pour the cleaning/sanitizing solution into a clean,
empty pail. Place the syrup line with the old syrup
connector into the pail of cleaner.
3. To place the left freezing cylinder in the Sanitize
mode, press the MENU (SELECT) key. Move the
cursor by pressing the AUTO (- ->) key until the third
line indicates RINSE / SANITIZE. Press the MENU
(SELECT) key. Move the cursor under the word
SANITIZE.
Pressing the MENU (SELECT) key will give you the
option to sanitize the left cylinder. Move the cursor
under the word YES. Pressing the MENU (SELECT)
key at this time will start the flow of cleaner/sanitizer
through the syrup system into the freezing cylinder.
4. Repeat step 1 through step 3 for the right freezing
cylinder.
Note:
Both sides of the machine have an LCD for
the two freezing cylinders located directly below it.
There is a left and a right freezing cylinder for each
LCD.
5. Open the prime plugs. Allow each cylinder to fill
approximately two thirds full. Close each prime plug.
6. Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of each relief
valve and begins draining into the front drip tray. The
relief valves are located at the top of each mix tank.
Press the OFF (<- -) key.
7. Press the BEATER (- - -) key to agitate the solution in
each freezing cylinder for 5 minutes.
Figure 6-40
8. With a pail beneath the door spouts, open the draw
valves and drain all the solution from the freezing
cylinders. Press the OFF (<- -) key and close the
draw valves.
9. Repeat step 1 through step 7 for the other side of the
machine.
RINSE / SANITIZE
RINSE
SANITIZE
EXIT
- - - - -
L
E
S
>
-
-
-
-
<
SANITIZE
LEFT
SIDE
YES
NO
- - -
L
E
S
>
-
-
-
-
<
13039b
Summary of Contents for C302
Page 10: ...2 2 TO THE OPERATOR Model C302 To the Operator 2 Notes...
Page 14: ...3 4 SAFETY Model C302 Safety 3 Notes...
Page 40: ...7 2 OPERATOR CHECKLIST Model C302 Operator Checklist 7 Notes...
Page 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 Parts Replacement Schedule 9 Notes...
Page 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C302 Limited Warranty on Equipment 10 Notes...
Page 52: ...11 4 LIMITED WARRANTY ON PARTS Model C302 Limited Warranty on Parts 11 Notes...