OPERATING PROCEDURES
6-7
Model C302
Operating Procedures
6
9. Repeat step 6 through step 8 for the right freezing
cylinder.
Note:
There is a left and a right freezing cylinder for
each LCD.
10. Open the prime plugs. Place an empty pail under the
door spouts. When sanitizing solution fills the
freezing cylinders approximately 2/3 full, close the
prime plugs.
Figure 6-25
11. Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of the relief
valve at the top of the mix tank and begins draining
into the front drip tray. Press the OFF (<- -) key.
12. Press the BEATER (- - -) key. Agitate the solution in
the freezing cylinders for 5 minutes.
Figure 6-26
13. With a pail beneath the door spouts, open the draw
valves and drain all the solution from the freezing
cylinders. Press the OFF (<- -) key and close the
draw valves.
Figure 6-27
14. Disconnect the syrup connectors in the sanitizing
solution.
15. Repeat these steps for the other side of the machine.
Priming/Brixing
1. Connect the syrup line to the Bag-in-Box (BIB) syrup.
2. Remove the drip tray, splash shield, and lower front
panel to gain access to the syrup sampling valves.
3. Open the prime plug.
Figure 6-28
SANITIZE
RIGHT SIDE
YES
NO
- - -
L
E
S
>
-
-
-
-
<
11228
13039b
13039o
11229
Summary of Contents for C302
Page 10: ...2 2 TO THE OPERATOR Model C302 To the Operator 2 Notes...
Page 14: ...3 4 SAFETY Model C302 Safety 3 Notes...
Page 40: ...7 2 OPERATOR CHECKLIST Model C302 Operator Checklist 7 Notes...
Page 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 Parts Replacement Schedule 9 Notes...
Page 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C302 Limited Warranty on Equipment 10 Notes...
Page 52: ...11 4 LIMITED WARRANTY ON PARTS Model C302 Limited Warranty on Parts 11 Notes...