TO THE INSTALLER
1-3
Model 104
To the Installer
1
4. Route incoming permanent wiring through the
7/8 in. (22 mm) hole in the base pan.
5. Connect two power supply leads. Attach the ground
(earth) wire to the grounding lug inside the electrical
box.
6. Make sure the machine is properly grounded before
applying power.
Beater Rotation
NOTICE!
Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
To correct the rotation on a three-phase unit, interchange
any two incoming power supply lines at the freezer main
terminal block only. To correct rotation on a single-phase
unit, exchange leads inside the beater motor. (Follow the
diagram printed on the motor.)
Electrical connections are made directly to the terminal
block provided in the main control box located behind the
service panel.
It is recommended that beater rotation service be
performed by a Taylor service technician.
Refrigerant
CAUTION!
This machine contains fluorinated
greenhouse gases (F-Gas) to provide refrigeration using
a hermetically sealed circuit or within foam insulation.
This machine’s type of gas, quantity, Global Warming
Potential (GWP), and CO
2
tonnes equivalent information
is recorded on the machine’s data label. The refrigerant
used is generally considered nontoxic and
nonflammable. However any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder approximately 80% will allow for
normal expansion.
CAUTION!
Use only approved refrigerant
listed on the machine's data label or authorized through a
manufacturer's technical bulletin. The use of any other
refrigerant may expose users and operators to
unexpected safety hazards.
WARNING!
Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush the area immediately with cold water. If burns are
severe, apply ice packs and contact a physician
NOTICE!
Taylor reminds technicians to be
aware of and in compliance with local government laws
regarding refrigerant recovery, recycling, and reclaiming
systems. For information regarding applicable local laws,
please contact your local authorized Taylor distributor.
IMPORTANT!
Refrigerants and their
associated lubricants may be extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
Summary of Contents for 104
Page 8: ...1 4 TO THE INSTALLER Model 104 To the Installer 1 Notes...
Page 14: ...3 4 SAFETY Model 104 Safety 3 Notes...
Page 18: ...4 4 PARTS Model 104 Parts 4 Notes...
Page 30: ...7 2 OPERATOR CHECKLIST Model 104 Operator Checklist 7 Notes...
Page 32: ...8 2 TROUBLESHOOTING Model 104 Troubleshooting 8 Notes...
Page 34: ...9 2 PARTS REPLACEMENT SCHEDULE Model 104 Parts Replacement Schedule 9 Notes...
Page 40: ...11 4 LIMITED WARRANTY ON PARTS Model 104 Limited Warranty on Parts 11 Notes...