5-2
USER INTERFACE
Model 104
User Interface
5
Once the desired time is set, put the control switch into
the AUTO position. The compressor and beater motor
operate until the time is up. When the timer setting
elapses, the refrigerating process is canceled. The dial
light and beater assembly continues to operate. A tone
sounds, signaling the operator to dispense the finished
product. Turn the control switch to the EJECT position.
The product is ready to draw off and serve.
Start with 5 minutes and increase as needed. Times and
temperatures are dependent on specific mix
formulations, pre-charge amounts, and finished product
preferences.
Note:
Because the freezing cylinder for the first batch
is at room temperature, the first batch freeze-down time
will be longer than subsequent batches.
Door Hinge
The door hinge (4) allows you to open the door without
removal. This feature is primarily used when changing
flavors and cleaning up is necessary.
Reset Condition
Model 104 is equipped with an internal motor overload
protection. Should an overload occur, the reset
mechanism trips, canceling freezer operation. To
properly reset the freezer, put the control switch into the
OFF position. Allow the beater motor to cool. Then return
the control switch to its original position.
Note:
If the unit went out on reset, the product may
have been run too cold or too long. Therefore, after
resetting the freezer, check the temperature control or
the time set.
.
Summary of Contents for 104
Page 8: ...1 4 TO THE INSTALLER Model 104 To the Installer 1 Notes...
Page 14: ...3 4 SAFETY Model 104 Safety 3 Notes...
Page 18: ...4 4 PARTS Model 104 Parts 4 Notes...
Page 30: ...7 2 OPERATOR CHECKLIST Model 104 Operator Checklist 7 Notes...
Page 32: ...8 2 TROUBLESHOOTING Model 104 Troubleshooting 8 Notes...
Page 34: ...9 2 PARTS REPLACEMENT SCHEDULE Model 104 Parts Replacement Schedule 9 Notes...
Page 40: ...11 4 LIMITED WARRANTY ON PARTS Model 104 Limited Warranty on Parts 11 Notes...