14
ANTI-FREEZE FUNCTION
When the device is off and the temper
-
ature surrounding the temperature sen
-
sor drops to below 6° C, the device will
switch on automatically. This is to pre
-
vent the heating agent inside the radia
-
tor from freezing. The activation of Anti-
freeze mode is indicated by the blinking
of the middle diode.
DRYER (TIMER) MODE
The DRYER mode switches the appli
-
ance on for a specified time, e.g. to dry
the towel. After this time the device
will automatically return to its previous
mode or setting. The default operation
time of the dryer mode is 2 hours.
To modify it (1-5 hours), press and hold
the
key – single LEDs will flash one af
-
ter the other. Each of them shines for
two seconds and indicates a specific set
-
ting of Timer – the first LED means 1h,
the second – 2h etc. After the 5th di
-
ode stops flashing, the 1st one starts the
flashing loop from the beginning. At the
moment of releasing the button, the se
-
lected LED lights up for 2 seconds. This
means that the corresponding setting
has been saved.
1.
To enable the DRYER function – press
the
key briefly while the appliance
is in operation. The temperature level
can be freely adjusted (
and but-
tons), and after a programmed time
the heater will return to the previ-
ous temperature setting (before the
DRYER function was activated).
2.
To use the function as a timer, the
heating element must be switched
off. Turn it on by pressing the
but-
ton. After the set time has elapsed,
the heater will turn off automatically.
Press the button at any time to inter
-
rupt the DRYER / TIMER mode.
CALIBRATING THE TEMPERATURE SPAN
The standard temperature span of the
heating element is 30-60° C. It is possible
to increase or decrease that span by set-
ting a maximum temperature of between
45° C and 65° C, (minimum temperature
of 30° C stays unchanged). This allows the
user to achieve a maximum temperature
which is higher than the standard or to ef
-
fectively heat a space with the device dur
-
ing lower surrounding temperatures.
Example: for the temperature regulation
span of up to 45° C (30-45° C) modifi
-
cation by one step (one diode), means
increase/decrease of temperature by
Summary of Contents for TWIST