150°
When installing the heating element
horizontally, the single tube (capillary)
where the temperature sensor is locat
-
ed, should be positioned to be as close
to the bottom of the radiator as possible.
BEFORE INSTALLATION OR FIRST USE:
1.
Read the chapter
Safety requirements
— Installation.
2.
Fit the heating element using the cor
-
rect spanner (size
22).
3.
The heating element must be installed
at the bottom of the radiator, perpen
-
dicular to the radiator pipes, while pre-
serving space for the proper circula
-
tion of the heating medium.
4.
Use a suitable heating medium for fill-
ing the electric radiator, i.e. (water,
special products based on water and
glycol for use in central heating sys
-
tems, or oil which complies with the
requirements of the manufacturer of
the radiator and heating element).
5.
Check the distances between the in
-
dividual heating element tubes and
bend if necessary.
5 mm
2-3 mm
6.
Do not switch the heating element
on if it is not fully immersed in radia
-
tor heating medium.
7.
Make sure an adequate air cushion is pre-
sent to protect against excessive pres-
sure build up within the heater (always
leave one of the radiator valves open).
8.
When filling the radiator with hot liq
-
uid insure that the liquid temperature
does not exceed 65° C.
9.
Follow the subsequent guidelines when
connecting the electrical installation:
a.
Brown wire — live connection to the
circuit (L).
b.
Blue wire — connect to neutral (N)
c.
Yellow & green wire — earth con
-
nection (PE).
10.
Before filling the radiator with heating
medium, ensure that the heating ele
-
ment is fitted properly and that it is wa
-
ter tight.