6.3 Wiring examples of the inputs and outputs
•
Requirements inpu
t: The external start pulse of the thread tapping unit should
happen by an external manual button. (Only with feed system for the spindle)
Attention: By operating „Stop! User“ during the operation the operation can be
cancelled.
This function is no
Emergency Stop
function!
1
2
3
+24 V
start 1
X363
•
Requirement input:
The external start puls of the thread tapping unit should happen
by an inductive proximity switch.
(Only with feed system for the spindle)
Wire the input automation (X364/3 Start 2) with an inductive proximity switch PNP.
br
bk
bl
+24 V
A
GND
1
2
3
4
GND
+24 V
start 2
X364
•
Requirement exit:
A relais or a valve for a clamping unit should be connected.
Wire the exit automation (X366) with a relais or a valve.
Respect the direction of the freerunning diode if present. (A freerunning diode is not
neccessary)
1
2
3
GND
-
+
X366
•
Requirement exit:
A warning lamp with horn should be installed for quality control.
Wire the exit signal column (X365) with various lamps and horn.
(You can order a signal column with horn as accessory)