13 Appendix A3: Spindle feed system
Scope of delivery
•
Air tube with quick fitting coupling
•
Foot switch
•
Feed is integrated in the thread tapping unit
Installation
•
Connect the connector (A) of the foot
switch with the machine.
•
For sensors you can connect the
connector (B) with the machine
alternatively.
•
Connect the compressed-air hose to the
fitting (C) and to the compressed-air.
compressed-air (58 - 116psi / 4 - 8bar)
cleaned with steam trap!
A
B
C
Commissioning
(D) Flow control for the speed operation
control
(E) Pressure control for the setting of the
feed force
Hand injury warnings respectivly
contusives!
D
E
•
Set at the pressure control (E) the desired feed force.
The feed force (C8) is shown in the display.
2,30
5,7
Nm
mm
5,7 mm
2,30
Nm
1000 rpm
M5 - 6
100%
250 N
32
F
1256 I 14
C8
Depth:
Torque:
Rotation speed:
If the value (C8) is out of the range it becomes red.