36
4.4.5 Quality parameter
4.4.5.1 Torque window
Option:
off / on
It is possible, if confirmed, to set
torque tolerance
starting
from 0.1 Nm
.
Torque used during processing must not exceed maximum torque in the
task menu and the maximum torque, less torque tolerance.
Measuring range is set between
start depth
and
stop depth
.
(stop depth e.g. for tap clearance hole)
(See chapter: "Quality Notifications")
4.4.5.2 Blowhole detection
Option:
on / off
You can set the
torque decrease
in %
(5 - 95%).
End of the measuring range is set by stop depth.
(stop depth e.g. for tap clearance hole)
(See chapter: "new messages")
4.4.5.3 Counter
4.4.5.3.1 Day counter
Option:
on
You can
reset
the day counter.
The day counter is
not
reset when the machine is switched on.
Display while processing:
A
good thread (green)
bad thread (red)
2,30
5,7
Nm
mm
1256 I 14
4.4.5.3.2 Workpiece counter
Option:
off / on
You can set different counter variants and values.
Option:
Abort after confirmation
- The last part
can
be reset in case of an
error by confirming the start button.
Abort after a faulty thread
- Last thread
must
be reset by confirming
the start button in case of an error. The next processing is blocked.
The display shows the following message in parameter area C13