Set in the main menu/lubricant settings of the operation unit (2) the desired parameters:
- Lubricant pulse:
Time of lubricant pulse. (delay after start)
- Air pulse:
Time for the air which takes the forwarded lubricant by the air pulse.
The lubricant will be sprayed by this.
- Blow out pulse:
Time for the blow out pulse after operation or chip clearance with
chip clearance throw out depth.
100%
32
0,7 s
0,2 s
0,3 s
C4 C5
C3
Display in the parameter area::
C3 Lubricant pulse
C4 Air pulse
C5 Blow out pulse
•
Open the cover (G1) of the lubricant tank and fill in the lubricant. Close cover (G1).
•
Bleeding:
Open the clamp lever (H2) and set the quantity control (H1) approx the value 4
to advance enough lubricant.
Turn on the following function:
Main menu/Lubricant settings/Lubricating pulse/Test continuous pulse. When the
lubricant is delivered from the nozzle (K), turn the flow control knob (H1) to the desired
value and clamp it with the clamping lever (H2).
•
Lubricant pulse:
The lubricating impulse delivers a small amount of lubricant through a
dosing pump. This function forms a drop dosage.
Function:
The piston pump is charged with lubricant in the idle state (machine off).
The piston pump is not charged with lubricant when the machine is at rest (machine on).
When a lubricating impulse is given, the piston pump returns and is charged with
lubricant. After the set time, the piston pump triggers the lubrication.
Therefore the set time is a delay of the lubrication.
This method prevents gassing of the lubricant and a continuous function with small
quantities. For quantities below 1 a time of 0.1 seconds should be set. If the time is too
short, it will not be sufficient for the charging process.
•
Air pulse:
For small quantities (flow regulator (H1) below 0.5) the function main
menu/lubricant settings/air impulse on is required, because the drop becomes too small
to detach from the nozzle (K) (adhesion force).
You can regulate the air volume with the adjustment screw for lubricating air (I). The
adjustment screw (I) should not be more than 2 turns (spray mist formation).
This function in connection with the lubricating impulse forms a spray dosage.
•
Air pulse without lubricant pulse:
This function can be used with lubricanting materials
or for dry processing for cooling.
•
Outblow pulse:
The outblow pulse is used to clean the tool or to remove chips (Setting:
Main menu/Lubricant settings/Blowout pulse).
The quantity of air is controllable by the adjusting screw (J).
•
Adjusting of the nozzle:
Align the noozle (K) with the
blow out drilling (K2) to the bottom
.
Adjust the nozzle to the tap hole to ensure a lubrication
during the whole working process.
K
K2