Introduction

This manual is intended only for qualified technical personnel 

No information contained in this manual can be considered of interest for the end user.

This manual is attached to the serial T-COMM, it should therefore not be used for different pro-

ducts.

WARNINGS:

The serial interface T-COMM is designed for the management of 2 automations simultaneously.

The control units are connected to each other via the serial interface T-COMM, synchronizing 

the movements of the two automated systems making them, in fact, a single installation.

Any other use is improper and, therefore, prohibited by regulation.

In the design of its equipment, TAU observes all applicable standards (see the attached decla-

ration of conformity); it is fundamental that the installer, in establishing installations, continue in 

strict compliance with the rules.

Unqualified personnel or unaware of the standards applicable to the “automatic gates and do-

ors” must absolutely refrain install systems.

Those who break the regulations are liable for damages that the system may cause!

You should carefully read all instructions before proceeding with the installation.

GENERAL CHARACTERISTICS

The product is designed and manufactured by TAU Srl, it complies with current safety 

standards.

Warranty 24 months (if not tampered with).

The performances shown are valid only if the product installation is successful, within 

the technical information given in this instruction manual.

RS485 SERIAL INTERFACE T-COMM

The serial interface T-COMM allows at 2 control panels to communicate with each other in MA-

STER / SLAVE mode.

A control unit must be set as MASTER, the second is automatically configured as SLAVE at the 

first pulse sent from the MASTER unit (see sect. “Installation RS485 serial interface T-COMM”). 

The MASTER unit assumes the logical system control.

It is usable with all the control panels (for a single motor) of the DIAMOND series.

PACKAGE CONTENTS

-   N ° 2 serial interfaces RS485;

-   2 connecting cables (control unit - RS485 serial interface) - 4 poles.

PRELIMINARY ADVICES

-   ICommands (PEDESTRIAN, OPEN, OPEN / CLOSE, STOP) must be connected only in the 

MASTER unit.

-   The radio receiver must be programmed only in the MASTER unit.

-   The photocells can be connected both in the MASTER or in the SLAVE control panel.

-   The safety edges can be connected both in the MASTER or in the SLAVE control panel (if 

not used, jumper the corresponding inputs).

-   The obstacle detection is independent in each control unit.

-   Set independently, on each control panel, the “automation” model (dip-switches 9, 10 ,11).

-   After  setting  the  MASTER  /  SLAVE  communication,  the  system  will  become  a  single 

automation,therefore it will not possible to operate only a single automation individually.

Summary of Contents for T-COMM

Page 1: ...ALACI N T COMM Interfaccia seriale RS485 RS485 serial interface Serielle Schnittstelle RS485 Activateur RS485 Interfaz serie RS485 Via Enrico Fermi 43 36066 Sandrigo VI Italia Tel 39 0444 750190 Fax 3...

Page 2: ...e safety microswitch Common Common Pedestrian Int Photocell Fixed safety edge 18V 1 Ext Photocell Common Extern Photoce RX 1 2 3 4 5 TX 1 2 Intern Photoce RX 1 2 3 4 5 TX 1 2 CONFIGURAZIONE MASTER SLA...

Page 3: ...FF 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 J4 7 nal ells nal ells Stop R S M Common Common Int Photocell Fixed safety edge 18V 1 Ext Photocell Common RX 1 2...

Page 4: ...URATION MASTER SLAVE AVEC 2 JEUX DE PHOTOCELLULES T COMM A B K126MA MASTER ON 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 J4 7 Open Close Stop Release safety mi...

Page 5: ...MA SLAVE OFF 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 J4 7 Internal Photocells Stop R S M Common Common Int Photocell Fixed safety edge 18V 1 Common TX 1 2 R...

Page 6: ...MASTER SLAVE AVEC 2 JEUX DE PHOTOCELLULES T COMM A B K206MA MASTER ON 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 J4 7 Master Photocells Open Close Stop Common...

Page 7: ...5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 J4 7 Slave Photocells Stop Common Common Close Fixed safety edge 0 V 18 V Photocell N C Common RX 1 2 3 4 5 TX 1 2 Stop Swi...

Page 8: ...anzia 24 mesi salvo manomissioni Le prestazioni indicate hanno validit solo se l installazione del prodotto viene eseguita correttamente rispettando le indicazioni tecniche riportate in questo manuale...

Page 9: ...settaggi di questi dip switches sulla centrale SLAVE non hanno influenza I dip swithes dal n 9 al n 12 sono in uso su entrambe le centrali ATTENZIONE nel caso si renda necessario modificare i paramet...

Page 10: ...acchine 2006 42 CE Dichiara inoltre che questo prodotto conforme ai requisiti essenziali di sicurezza delle seguenti ulteriori direttive CEE 2006 95 CE Direttiva Bassa Tensione 2004 108 CE Direttiva C...

Page 11: ...ety standards Warranty 24 months if not tampered with The performances shown are valid only if the product installation is successful within the technical information given in this instruction manual...

Page 12: ...settings of these dip switches on the SLAVE have no influence The dip switches from N 9 to N 12 are in use on both control panels WARNING In case should it be necessary to change the working paramete...

Page 13: ...hat this product complies with the essential safety requirements of the following EEC directives 2006 95 EC Low Voltage Directive 2004 108 EC Electromagnetic Compatibility Directive and where required...

Page 14: ...Umfang von TAU S r l entwickelt und hergestellt und entspricht den geltenden Sicherheitsbestimmungen Die Garantie betr gt 24 Monate unbefugte Eingriffe ausgenommen Die angegebenen Leistungen beziehen...

Page 15: ...8 nur im MASTER Ger t aktiv die Einstellungen dieser Dip Switches auf dem SLAVE Ger t haben keinen Einfluss Die Dip Switches 9 bis 12 sind auf beiden Ger ten in Gebrauch ACHTUNG Sollte es notwendig w...

Page 16: ...er dass dieses Produkt den grunds tzlichen Sicherheitseigenschaften der folgenden Richtlini en EWG entspricht 2006 95 EG Niederspannungsrichtlinie 2004 108 EG Richtlinie f r elektromagnetische Kompati...

Page 17: ...mmagement accidentel except Les performances de l activateur indiqu es ne sont possibles que gr ce une correcte installation du produit dans le respect des indications techniques fournies dans ce mode...

Page 18: ...rale MASTER le r glage des m mes dip switches sur la centrale SLAVE n a pas d importance Les dip swithes du n 9 au n 12 sont activ s sur les deux centrales ATTENTION Pour toute variation des param tre...

Page 19: ...autre part que ce produit est conforme aux exigences essentielles de s curit des directives CEE sui vantes 2006 95 CE Directive Basse Tension 2004 108 CE Directive Compatibilit lectromagn tique et si...

Page 20: ...Garant a 24 meses si no manipulado Las actuaciones que se muestran son v lidas s lo si la instalaci n del producto se realiza cor rectamente respetando la informaci n t cnica contenida en este manual...

Page 21: ...witches en la central SLAVE no tiene ninguna influencia Los dip switches del No 9 a No 12 est n en uso en ambas centrales ATENCI N en caso de que sea necesario cambiar los par metros de trabajo a trav...

Page 22: ...a tambi n que este producto cumple con los requisitos esenciales de seguridad de las siguientes ulteriores directivas CEE 2006 95 CE Directiva Baja Tensi n 2004 108 CE Directiva Compatibilidad Electro...

Page 23: ...23...

Page 24: ...0376 info tauitalia com www tauitalia com Foglietto illustrativo CARTA Raccolta differenziata Segui le indicazioni del tuo comune N B togliere i punti metallici Instruction leaflet PAPER Waste separat...

Reviews: