English
EN16005
1. DESCRIPTION
4. MOUNTING PRECAUTIONS
6. MOUNTING & WIRING INFORMATION
8. DETECTION AREA WIDTH AND DEPTH ADJUSTMENT
7. DIP SWITCH SETTINGS
2. DIMENSIONS
3. LED INDICATORS
5. TECHNICAL SPECIFICATIONS
DOORRAD2
User Manual (Original)
COMPLIED STANDARDS
DIN18650-1:2005
EN 12978:2003
EN 16005:2012
EC type examination 44 205
12 414283-001
Indicator LED
(Red, Green & Blue)
Base
Area Mask
(Inner 3 Rows)
Area Mask
(Outer 2 Rows)
Detection Window
Potentiometer
(Sensitivity Volume)
Connector
Depth Adjustment
Lever Arm
(Inner 3 Rows)
Cover
Depth Adjustment
Lever Arm
(Outer 2 Rows)
Dip Switch
Dip Switch
Installation
Instruction
Accessories
Mounting Template
Cable
Mounting Screws
(2 pcs.)
X
Y
Mounting height
is 3m (9.84ft) or
lower.
Mount within 50mm
from the bottom of the
door engine cover.
Ensure there are no
moving objects in the
detection zone.
Ensure no condensation
gets onto the sensor.
3.0m
(9.84ft)
Max
50mm
If the sensor is exposed
to excessive rain install
with a weather cover.
If possible ensure no
accumulation of snow or
water on the floor.
Ensure the minimum of
reflected sunlight from
the floor.
Use different frequency
settings for sensors in
close proximity.
A
B
To maximize the effectiveness of doorway detection, install the DOORRAD2 outside and inside as shown below.
Side View
A
B
Moving Door Leaf
Moving Door Leaf
A
B
Plan View
!
WARNING
Drilling may cause electric shock.
Be careful of hidden wires inside the door engine cover.
1 Attach the mounting template wi th i t s bot tom parallel
to the same position as the bottom edge of the door engine
cover.
2 Drill holes for mounting (3.5mm Ø) and wir-
ing (10mm Ø) holes.
3 If you need to remove the sensor body from its base then
lift the sensor body from the base and tilt it forward to remove
as illustrated.
4 Attach the sensor with the mounting
screws provided.
50mm
50mm
1
1
2
5 -1 Wiring to a door controller that
can
test the sensor.
5 -2 Wiring to a door controller that
cannot
test the sensor.
Sensor’s
Cable
Cable
Red
Black
White
Green
)
Gray(+)
R2,3,4,5
Output
AC/DC
12 to 24 [V]
±10%
R1,2
Output
Collector
Emitter
N.O.
COM
Power
(Non Pole)
Test Input
Test-P
Test-N
Set “Test input” dip switch
setting Y 6 to “ON”
Ref section 7, Dip Switch
Settings.
ON
6
Note
OFF
Y
Blue(-)
Brown(-)
EN16005
Set “Test input” dip switch
setting Y 6 to “OFF”
Ref section 7, Dip Switch
Settings.
Note
Sensor’s
Cable
Cable
Red
Black
White
Green
)
Blue(-)
Gray(+)
R2,3,4,5
Output
AC/DC
12 to 24 [V]
±10%
R1,2
Output
Collector
Emitter
N.O.
COM
Power
(Non Pole)
ON
6
OFF
Y
do not connect
do not connect
Brown(-)
6 House connectors in the receptacle.
7 Replace Cover.
Depth Adjustm
ent Lever Arm
!
WARNING
Be careful not to inadvertently move the Depth Adjustment
Lever Arms when replacing the cover.
Detection Area Depth Adjustment: Inner 3 Rows
Detection Area Width Adjustment
Detection Area Depth Adjustment: Outer 2 Rows
1.0
[m]
Inner 3
rows
adjustment
lever arm
0
2.2
Door
2.0
1.0
3.0
0.5
1.0
[m]
0
2.2
Door
2.0
1.0
3.0
0.5
1.5
1.5
[-8
degree]
setting
[0
degree]
setting
With
Base
Area
Mask
(Inner
3
Rows)
Area
Mask
(Outer
2
Rows)
0
1.0
2.0
3.0[m]
2.0
1.0
1.0
2.0
Narrow
Wide
Width
Narrow
Wide
Outer 2 rows
adjustment
lever arm
0
2.2
2.0
1.0
3.0
2.0
1.0
[m]
[0
degree]
setting
0
2.2
2.0
1.0
3.0
2.0
1.0
[m]
3.0
[+10
degree]
setting
With
Base
[m]
1.0
0
2.2
Door
2.0
1.0
3.0
0.5
Door
0
2.2
2.0
1.0
3.0
1.0
0.5
[m]
Without
Base
[-8
degree]
setting
[0
degree]
setting
0
2.2
2.0
1.0
3.0
2.0
1.0
[m]
[0
degree]
setting
0
2.2
2.0
1.0
3.0
2.0
1.0
[m]
[+10
degree]
setting
Without
Base
!
CAUTION
The above illustrated detection areas represent the actual position of the infrared beams. The actual detection area observed will vary depending on the sensor
installation environment, object been detected and sensor settings. Please ensure that the detection area is set to conform to EN16005.
!
CAUTION
Is advisable to turn off and on again the radar
after each adjustment of the DIP switches.
Dip Switch Z
O
N
O
N
Dip Switch Y
1 2 3 4
O
N
Dip Switch X
1 2 3 4
1 2 3 4 5 6
!
ATTENTION! Every time you change a DIP SWITCH, make sure to turn the power off the radar.
= Default Setting
Function
Dip Switch X
Description
Possible Setting Options
Presence
Timer
30s
1 2
The sensor will detect a stationary object for the period of the preset
presence timer setting on the inner 3 rows.
2s
1 2
30s
1 2
1 2
60s
1 2
∞
EN16005
To comply with EN16005 set the presence timer to 30s
or more.
Quantity of
Detection
Rows
R5
3 4
The number of rows of detection can be set to 5, 4, 3, 2 depending on
detection area requirements.
3
Rows ON
2
Rows ON
4
Rows ON
5
Rows ON
R5
3 4
R4
3 4
R3
3 4
R2
3 4
Frequency
A
1 2
When more than two sensors are installed in close proximity to each
other select different frequency settings for each sensor to prevent
cross interference.
A
1 2
B
1 2
1 2
1 2
C
D
Safety
Relay
Output
3
N.O.
Refer to [11.Timing Chart of events] for full details on Safety Output.
N.O.
N.C.
Safety Output (Opto-Coupler)
7
N.O.
N.C.
Reflection
Diagnostics
4
Normal
A low reflected infrared signal is indicated by a slow flashing Red/Green
LED.
To ignore this low reflection error, set this dip switch to “Low
Reflection”(ON).
Transmitter
Receiver
IR Spot
Receiver
IR Spot
Transmitter
LED
Low Ref.
8
8
Normal
EN16005
To comply with EN16005 set to “Normal”.
Function
Dip Switch Y
Description
Possible Setting Options
Direction
Detection
1
OFF
When set to ON, pedestrians moving away from the sensor will not be
detected.
ON
1
1
OFF
Note
For pedestrian safety purposes when “Doorway Learn”
is set to ON the 1st and 2nd row of detection will detect
pedestrians regardless of direction of movement.
Activation
Relay
Output
2
N.O.
Refer to [11.Timing Chart of events] for full details on Activation Output.
N.O.
N.C.
2
Activation Output (Mechanical Relay)
Monitor
Mode
3
Normal
Set to Snow in instances where false door activations can result from
blowing snow, leaves or rubbish in the door close area.
Snow
3
3
Normal
Door Hold
4
Auto
!
CAUTION
Switch to OPEN to hold the door in the open position.
Open
4
4
Auto
Doorway
Learn
OFF
5
Doorway Learn allows the 1
st
row of detection to be focused
inside the door close area without detecting the door movement.
Door
OFF
ON
5
5
Door
Note
When Doorway Learn is turned ON, the sensitivity level
of the inner row of detection is only at maximum when
the outer rows of detection are activated.
75mm(2.95") = Standard Mounting Pitch
25mm
(0.98")
15mm
(0.59")
35mm
(1.37")
10mm
(0.39")
230mm(9.06")
44mm
(1.73")
70
.4
m
m
(2
.7
7"
)
66
.5
m
m
(2
.6
2"
)
33.5 mm
(1.32")
Green
Standby.
Green blinking
Doorway Learning (When dip switch Y 5 is ON).
Blue
ROW 4,5 Detecting.
Red
ROW 1,2,3 Detecting.
Orange
Detection row “ROW1”(“ROW2” when doorway
Learning is turned ON) is detecting door movement.
Orange blinking (Fast)
Indicates a change of dip switch settings.
Orange blinking (Slow)
Door Hold is turned Open (When dip switch Y 4 is Open).
Green/Red blinking (Fast)
Internal Sensor Error.
Green/Red blinking (Slow) Reflected infrared signal from the floor is very low.
Model Name
DOORRAD2
Detection Method
Active Infrared Reflection
Installation Height
3.0[m] (9.84 [ft]) Max
Supply Voltage
AC/DC 12 to 24 [V] ±10% 50/60Hz
Power Consumption
AC12V-2.1 [VA] (Max)
AC24V-2.1 [VA] (Max)
DC12V-110 [mA] (Max)
DC24V-60 [mA] (Max)
Output Holding Time
Approx. 0.5s
Response Time
0.1s ~ 0.2s
Presence Timer
Outer 2 Rows
1 [seconds]
Inner 3 Rows
2s,30s,60s
Output
ROW 1,2
Open collector: 7.5 [mA] (Max) Resistor Load
Opto coupler (NPN)
Voltage: 55 [VDC] Max. Current : 50 [mA] Max.
Dark Current: 100 [nA] Max. (Resistance load)
ROW 2,3,4,5
Form A Relay DC50 [V] 0.1[A] Resistor Load
Test Input
6 [mA] Max. @ 24 [VDC]
Operating Temperature
-20 to +60 [Deg.C],(-4 to 140 Deg.F)
Operating humidity
Below 80%
IP Rate
IP54 (With Base)
Category
2 , performance level D according to EN ISO 13849-1:2008
Weight
0.55 [lb.] (0.25 [kg])
Color
Black, Silver
Accessories
Cable, Mounting Screw 2pcs.,
Mounting Template, Installation Instruction
Notice: Specification may be changed without prior notice.
!
!
Note
WARNING
CAUTION
Disregarding this
symbol may result in
serious injury or death.
Disregarding this symbol may
result in injury or damage to
equipment.
Special attention is required
when this symbol is shown.
Setting required to conform with
EN16005.