tau DOORRAD2 User Manual Download Page 3

English

EN16005

 1. DESCRIPTION

 4. MOUNTING PRECAUTIONS

 6. MOUNTING & WIRING INFORMATION

 8. DETECTION AREA WIDTH AND DEPTH ADJUSTMENT

 7. DIP SWITCH SETTINGS

 2. DIMENSIONS

 3. LED INDICATORS

 5. TECHNICAL SPECIFICATIONS

DOORRAD2

User Manual (Original)

COMPLIED STANDARDS

DIN18650-1:2005

EN 12978:2003

EN 16005:2012

EC type examination 44 205

12 414283-001

Indicator LED

(Red, Green & Blue)

Base

Area Mask

(Inner 3 Rows)

Area Mask

(Outer 2 Rows)

Detection Window

Potentiometer

(Sensitivity Volume)

Connector

Depth Adjustment

Lever Arm

(Inner 3 Rows)

Cover

Depth Adjustment

Lever Arm

(Outer 2 Rows)

Dip Switch

Dip Switch

Installation 

Instruction

Accessories

Mounting Template

Cable

Mounting  Screws 

(2 pcs.)

X

Y

Mounting height

is 3m (9.84ft) or

lower.

Mount within 50mm

from the bottom of the

door engine cover.

Ensure there are no

moving objects in the

detection zone.

Ensure no condensation

gets onto the sensor.

3.0m

 

(9.84ft)

Max

 

50mm

If the sensor is exposed

to excessive rain install

with a weather cover.

If possible ensure no

accumulation of snow or

water on the floor.

Ensure the minimum of

reflected sunlight from

the floor.

Use different frequency

settings for sensors in

close proximity.

A

B

To maximize the effectiveness of doorway detection, install the DOORRAD2 outside and inside as shown below.

Side View

A

B

Moving Door Leaf

Moving Door Leaf

A

B

Plan View

!

WARNING

Drilling may cause electric shock.

Be careful of hidden wires inside the door engine cover.

1  Attach the mounting template wi th i t s bot tom parallel 

to the same position as the bottom edge of the door engine 

cover.

2  Drill holes for mounting (3.5mm Ø) and wir-

ing (10mm Ø) holes.

3  If you need to remove the sensor body from its base then 

lift the sensor body from the base and tilt it forward to remove 

as illustrated.

4  Attach the sensor with the mounting 

screws provided.

50mm

50mm

1

1

2

5 -1 Wiring to a door controller that 

can

 test the sensor.

5 -2 Wiring to a door controller that 

cannot

 test the sensor.

Sensor’s 

Cable

Cable

Red
Black
White
Green
)

Gray(+)

R2,3,4,5

Output

AC/DC

12 to 24 [V]

±10%

R1,2 

Output

Collector

Emitter

N.O.
COM

Power

(Non Pole)

Test Input

Test-P

Test-N

Set “Test input” dip switch 

setting  Y 6 to “ON”

Ref section 7, Dip Switch

Settings.

ON

6

Note

OFF

Y

Blue(-)

Brown(-)

EN16005

Set “Test input” dip switch 

setting  Y 6 to “OFF”

Ref section 7, Dip Switch

Settings.

Note

Sensor’s 

Cable

Cable

Red
Black
White
Green
)
Blue(-)
Gray(+)

R2,3,4,5

Output

AC/DC

12 to 24 [V]

±10%

R1,2

Output

Collector

Emitter

N.O.
COM

Power

(Non Pole)

ON

6

OFF

Y

do not connect
do not connect

Brown(-)

6  House connectors in the receptacle.

7  Replace Cover.

Depth Adjustm

ent Lever Arm

!

WARNING

Be careful not to inadvertently move the Depth Adjustment

Lever Arms when replacing the cover.

Detection Area Depth Adjustment: Inner 3 Rows

Detection Area Width Adjustment

Detection Area Depth Adjustment: Outer 2 Rows

1.0

[m]

Inner 3

rows

adjustment

lever arm

0

2.2

Door

2.0

1.0

3.0

0.5

1.0

[m]

0

2.2

Door

2.0

1.0

3.0

0.5

1.5

1.5

[-8

 

degree]

 

setting

[0

 

degree]

 

setting

With

Base

Area

 

Mask

 

(Inner

 

3

 

Rows)

Area

 

Mask

 

(Outer

 

2

 

Rows)

0

1.0

2.0

3.0[m]

2.0

1.0

1.0

2.0

Narrow

Wide

Width

Narrow

Wide

Outer 2 rows

adjustment

lever arm

0

2.2

2.0

1.0

3.0

2.0

1.0

[m]

[0

 

degree]

 

setting

0

2.2

2.0

1.0

3.0

2.0

1.0

[m]

3.0

[+10

 

degree]

 

setting

With

Base

[m]

1.0

0

2.2

Door

2.0

1.0

3.0

0.5

Door

0

2.2

2.0

1.0

3.0

1.0

0.5

[m]

Without

Base

[-8

 

degree]

 

setting

[0

 

degree]

 

setting

0

2.2

2.0

1.0

3.0

2.0

1.0

[m]

[0

 

degree]

 

setting

0

2.2

2.0

1.0

3.0

2.0

1.0

[m]

[+10

 

degree]

 

setting

Without

Base

!

CAUTION

The above illustrated detection areas represent the actual position of the infrared beams. The actual detection area observed will vary depending on the sensor 

installation environment, object been detected and sensor settings. Please ensure that the detection area is set to conform to EN16005.

!

CAUTION

Is advisable to turn off and on again the radar 

after each adjustment of the DIP switches.

   

Dip Switch Z

O

N

O

N

Dip Switch Y

1 2 3 4

O

N

Dip Switch X

1 2 3 4

1 2 3 4 5 6

   

!

ATTENTION! Every time you change a DIP SWITCH, make sure to turn the power off the radar.

 =  Default Setting

Function

Dip Switch  X

Description

Possible Setting Options

Presence

Timer

30s

1 2

The sensor will detect a stationary object for the period of the preset

presence timer setting on the inner 3 rows.

2s

1 2

30s

1 2

1 2

60s

1 2

EN16005

To comply with EN16005 set the presence timer to 30s 

or more.

Quantity of

Detection

Rows

R5

3 4

The number of rows of detection can be set to 5, 4, 3, 2 depending on

detection area requirements.

3

 

Rows ON

2

 

Rows ON

4

 

Rows ON

 

5

 

Rows ON

 

R5

3 4

R4

3 4

R3

3 4

R2

3 4

Frequency

A

1 2

When more than two sensors are installed in close proximity to each

other select different frequency settings for each sensor to prevent

cross interference.

A

1 2

B

1 2

1 2

1 2

C

D

Safety

Relay

Output

3

N.O.

Refer to [11.Timing Chart of events] for full details on Safety Output.

N.O.

N.C.

Safety Output (Opto-Coupler)

7

N.O.

N.C.

Reflection

Diagnostics

4

Normal

A low reflected infrared signal is indicated by a slow flashing Red/Green

LED.

To ignore this low reflection error, set this dip switch to “Low

Reflection”(ON).

Transmitter

Receiver

IR Spot

Receiver

IR Spot

Transmitter

LED

Low Ref.

8

8

Normal

EN16005

To comply with EN16005 set to “Normal”.

Function

Dip Switch  Y

Description

Possible Setting Options

Direction

Detection

1

OFF

When set to ON, pedestrians moving away from the sensor will not be

detected.

ON

1

1

OFF

Note

For pedestrian safety purposes when “Doorway Learn” 

is set to ON the 1st and 2nd row of detection will detect 

pedestrians regardless of direction of movement.

Activation

Relay

Output

2

N.O.

Refer to [11.Timing Chart of events] for full details on Activation Output.

N.O.

N.C.

2

Activation Output (Mechanical Relay)

Monitor

Mode

3

Normal

Set to Snow in instances where false door activations can result from

blowing snow, leaves or rubbish in the door close area.

Snow

3

3

Normal

Door Hold

4

Auto

!

CAUTION

Switch to OPEN to hold the door in the open position.

Open

4

4

Auto

Doorway

Learn

OFF

5

Doorway Learn allows the 1

st

 row of detection to be focused

inside the door close area without detecting the door movement.

Door

OFF

ON

5

5

Door

Note

When Doorway Learn is turned ON, the sensitivity level

of the inner row of detection is only at maximum when 

the outer rows of detection are activated.

75mm(2.95") = Standard Mounting Pitch

25mm

(0.98")

15mm

(0.59")

35mm

(1.37")

10mm

(0.39")

230mm(9.06")

44mm

(1.73")

70

.4

 m

m

(2

.7

7"

)

66

.5

 m

m

(2

.6

2"

)

33.5 mm

(1.32")

Green  

Standby.

Green blinking  

Doorway Learning (When dip switch  Y  5 is ON).

Blue  

ROW 4,5 Detecting.

Red  

ROW 1,2,3 Detecting.

Orange  

Detection row “ROW1”(“ROW2” when doorway

 

Learning is turned ON) is detecting door movement.

Orange blinking (Fast)  

Indicates a change of dip switch settings.

Orange blinking (Slow)  

Door Hold is turned Open (When dip switch  Y  4 is Open).

Green/Red blinking (Fast)  

Internal Sensor Error.

Green/Red blinking (Slow)   Reflected infrared signal from the floor is very low.

Model Name

DOORRAD2

Detection Method

Active Infrared Reflection

Installation Height

3.0[m] (9.84 [ft]) Max

Supply Voltage

AC/DC 12 to 24 [V] ±10% 50/60Hz

Power Consumption

AC12V-2.1 [VA] (Max)  

AC24V-2.1 [VA] (Max)

DC12V-110 [mA] (Max)  

DC24V-60 [mA] (Max)

Output Holding Time

Approx. 0.5s

Response Time

0.1s ~ 0.2s

Presence Timer

Outer 2 Rows

1 [seconds]

Inner 3 Rows

2s,30s,60s

Output

ROW 1,2

Open collector: 7.5 [mA] (Max) Resistor Load

Opto coupler (NPN)

Voltage: 55 [VDC] Max. Current : 50 [mA] Max.

Dark Current: 100 [nA] Max. (Resistance load)

ROW 2,3,4,5

Form A Relay DC50 [V] 0.1[A] Resistor Load

Test Input

6 [mA] Max. @ 24 [VDC]

Operating Temperature

-20 to +60 [Deg.C],(-4 to 140 Deg.F)

Operating humidity

Below 80%

IP Rate

IP54 (With Base)

Category

2 , performance level D according to EN ISO 13849-1:2008

Weight

0.55 [lb.] (0.25 [kg])

Color

Black, Silver

Accessories

Cable, Mounting Screw 2pcs.,

Mounting Template, Installation Instruction

Notice: Specification may be changed without prior notice.

!

!

Note

WARNING

CAUTION

Disregarding this 

symbol may result in 

serious injury or death.

Disregarding this symbol may

result in injury or damage to

equipment.

Special attention is required 

when this symbol is shown.

Setting required to conform with 

EN16005.

Summary of Contents for DOORRAD2

Page 1: ... 4 5 6 Attenzione ogni volta che si effettua una modifica sui DIP SWITCH togliere la tensione dal radar stesso impostazione di default Funzione Dip switch X Descrizione Possibili opzioni di impostazione Timer presenza 30s 1 2 Il sensore rileva corpi fermi in base all impostazione predefinita per il timer di presenza sulle 3 file interne 2s 1 2 30s 1 2 1 2 60s 1 2 EN16005 Per conformità al DIN18650...

Page 2: ...stazioni dip switch I problemi tecnici al sensore DOORRAD2 sono segnalati da un LED verde rosso lampeggiante La velocità di intermit tenza segnala il tipo di errore verificatosi come indicato sotto Velocità di intermittenza LED Cause Veloce Rosso Verde Si prega di sostituire il sensore Lento Rosso Verde Verificare che il potenziometro di sensibilità sia impostato al massimo quindi riattivare il se...

Page 3: ... 4 5 6 ATTENTION Every time you change a DIP SWITCH make sure to turn the power off the radar Default Setting Function Dip Switch X Description Possible Setting Options Presence Timer 30s 1 2 The sensor will detect a stationary object for the period of the preset presence timer setting on the inner 3 rows 2s 1 2 30s 1 2 1 2 60s 1 2 EN16005 To comply with EN16005 set the presence timer to 30s or mo...

Page 4: ... 7 8 Dip Switch X 2s 1 2 Low Ref 8 Refer to 7 Dip Switch Settings Technical problems with the DOORRAD2 sensor are indicated by a flashing Green Red LED The frequency of flashing indicates the type of problem as explained below Flash Frequency LED Cause Fast Red Green Please replace the sensor Slow Red Green Confirm that the sensitivity potentiometer is set to maximum and re power the sensor If the...

Page 5: ...IN DIP Schalter Z DIP Schalter X DIP Schalter Y 1 2 3 4 1 2 3 4 1 2 3 4 5 6 Achtung jedesmal eine Änderung auf dem DIP SWITCH bewirkt mußen Sie die Spannung von demselben Radar entfernen Grundeinstellung Funktion DIP Schalter X Beschreibung Einstellmöglichkeiten Präsenz Timer 30s 1 2 Der Sensor erkennt ein unbewegtes Objekt für die Präsenz Timer Voreinstel lung an den inneren 3 Reihen 2s 1 2 30s 1...

Page 6: ...r Einstellungen Technische Probleme des DOORRAD2 Sensors werden durch das Blinken einer grünen roten LED angezeigt Die Blinkfrequenz kennzeichnet die Art des Problems wie unten angeführt Blinkfrequenz LED Ursache Schnell Rot Grün Ersetzen Sie den Sensor Langsam Rot Grün Überprüfen Sie ob der Empfindlichkeits Po tentiometer auf sein Maximum eingestellt ist und aktivieren Sie den Sensor erneut Wenn ...

Page 7: ...ourant du radar Réglage par défaut Fonction Microinterrupteurs X Description Choix de réglages possibles Tempori sation sur présence 30s 1 2 Le capteur détectera un objet immobile pour le réglage de la valeur prédéter minée de la minuterie de présence sur les 3 rangées intérieures 2s 1 2 30s 1 2 1 2 60s 1 2 EN16005 Pour être en conformité avec la norme EN16005 réglez la minuterie de présence sur 3...

Page 8: ... s 1 2 Réfl faible 8 Voir 7 Réglages des micro interrupteurs Les problèmes techniques du capteur DOORRAD2 sont signalés par une DEL Verte Rouge clignotante La fréquence du clignotement indique le type de problème comme expliqué ci dessous Fréquence du clignotement DEL Cause Rapide Rouge Vert Veuillez remettre en place le capteur Lent Rouge Vert Vérifiez que le potentiomètre de sensibilité est bien...

Page 9: ...ión del propio radar Ajuste predeterminado Función Conmutador dip X Descripción Posibles opciones de ajuste Temporizador de presencia 30s 1 2 El sensor detectará un objeto estacionario para el ajuste del temporizador de presencia preajustado en las 3 filas internas 2s 1 2 30s 1 2 1 2 60s 1 2 EN16005 Para cumplir la norma DIN18650 ajuste el temporizador de presencia a un mínimo de 30 s Cantidad de ...

Page 10: ... 8 Consulte el apartado 7 Ajustes del conmutador dip Los problemas técnicos con el sensor DOORRAD2 se indican mediante el parpadeo de un LED verde rojo La frecuen cia del parpadeo indica el tipo de problema como se explica a continuación Frecuencia del parpadeo LED Cause Rápido Rojo Verde Sustituya el sensor Lento Rojo Verde Confirme que el potenciómetro de sensibilidad está ajustado y vuelva a en...

Reviews: