TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
28
CAUTION
It
is
forbidden
to
smoke
and
use
open
fire
in
the
immediate
vicinity
of
the
dispenser.
The
smoking
ban
applies
also
to
passengers
inside
the
vehicle.
It
is
forbidden
to
use
mobile
phones
in
the
immediate
vicinity
of
the
dispenser.
It
is
forbidden
to
pump
into
the
vehicle
tank
while
the
engine
is
running.
CAUTION
The
attendant
must
not
perform
any
repairs
of
the
device
and
change
setting
of
safety
fittings.
Regular
maintenance
and
service
may
only
be
performed
by
an
authorized
service
company.
The
attendant
must
keep
the
device
in
proper
and
safe
order,
immediately
inform
the
service
organization
about
the
defect
of
abnormality
during
operation
and
immediately
decommission
the
device
in
case
of
danger
of
default.
CAUTION
Technical
and
technological
devices
must
correspond
to
approved
conditions
together
with
regulations
for
safe
operation
and
maintenance
as
well
as
solutions
of
emergencies.
The
device
must
be
fitted
with
carbon
‐
dioxide
extinguishers
according
to
the
fire
‐
safety
solution.
The
CNG
fuel
station
may
only
be
operated
by
demonstrably
trained
persons.
The
dispenser
is
equipped
with
the
“STOP
button”
for
emergencies.
The
procedure
in
case
of
fire
or
emergency
is
precisely
defined
in
local
operating
rules
and
regulations
–
the
attendant
must
be
demonstrably
trained
with
regard
to
this.
It
is
necessary
to
observe
defined
terms
to
perform
regular
checks
and
inspections
of
all
installed
technical
devices.
Do
not
allow
persons
without
appropriate
professional
qualification
to
tamper
the
installed
technology
including
the
gas
devices.
CAUTION
It
is
forbidden
to
smoke
and
use
open
fire
in
the
immediate
vicinity
of
the
dispenser.
The
smoking
ban
applies
also
to
passengers
inside
the
vehicle.
It
is
forbidden
to
use
mobile
phones
in
the
immediate
vicinity
of
the
dispenser.
NOTICE
Each
CNG
dispenser
must
be
secured
with
an
electrical
device
equipped
with
the
STOP
function
according
to
category
0
or
1
in
EN
60204
‐
1.
The
fuel
station
attendant
must
be
familiar
with
the
device
function.
5.2.
DISPENSER
COMMISSIONING
Switching
ON
and
OFF
of
CNG
dispensers
is
carried
out
in
the
main
switchboard
of
the
fuel
station
where
the
power
supply
of
the
dispensers
is
provided:
test
of
display
units
(displays).
The
backlight
of
the
displays
lights
up
and
then
all
display
segments
(eights)
are
displayed
for
approx.
1
second
processor
unit
test.
Ten
‐
second
test
(countdown
9,
8,
…
1),
in
which
all
functions
and
memory
of
the
processor
unit
are
checked.
During
the
test,
the
following
is
displayed
in
sequence:
o
(9)
type
of
counter
restart
‐
STB
(service
data)
and
status
of
metrological
switches
SW1
‐
1
to
SW1
‐
4
located
on
the
processor
board.
The
switches
are
protected
against
unauthorized
switching
by
a
cover
fitted
with
a
metrological
seal.
(standard
state
is
1000
SW1
‐
1=ON,
SW1
‐
2,3,4=OFF)
o
(8)
(7)
(6)
(5)
version
and
checksum
of
the
metrologically
relevant
part
of
the
program
(1.02
and
24AD).
o
(4)
(3)
(2)
(1)
processor
board
type
‐
TBELTM
or
CLEAR
message,
in
case
of
parameter
initialization
with
switch
SW1
‐
4
=
ON
8888888
1888888
88888
9
Stb
1000
8
102
24Ad
1000