TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
26
This
function
allows
to
view
and
change
the
password
to
the
manager
mode.
The
setting
is
made
by
pressing
the
<E>
key
by
entering
a
new
password
in
<PPPP>
format
and
confirming
<E>
.
Parameter
Meaning
Factory
setting
P08
=
1
to
9999
Manager
mode
access
password
1111
4.1.13.
MAINTENANCE
HISTORY
(P09)
The
parameter
allows
you
to
display
the
identification
codes
of
the
last
50
service
remote
controllers
that
entered
into
service
mode
of
the
counter.
After
switching
to
parameter
P09,
the
code
of
the
last
service
remote
controller
(e.g.,
19235)
appears
on
the
quantity
display
line.
After
pressing
the
<+>
key,
the
penultimate
remote
controller
code
will
appear.
After
pressing
the
<E>
key,
the
date
and
time
of
entering
the
service
controller
into
the
setting
mode
of
the
dispenser
counter
will
appear
on
the
display
(e.g.,
24.8.2021
at
12:51:01).
Parameter
Meaning
P7
‐
00
Code
of
the
last
remote
controller
P7
‐
01
Code
of
penultimate
service
controller
…
…
P7
‐
49
Code
of
the
50th
service
controller
in
the
sequence
4.1.14.
SERIAL
NUMBERS
OF
THE
PERIPHERAL
UNITS
(P10)
The
parameter
is
used
to
display
the
serial
numbers
of
the
connected
peripheral
units.
The
actual
serial
numbers
of
the
peripheral
units
are
compared
with
the
numbers
stored
in
the
processor
unit
memory.
If
a
mismatch
is
detected,
an
error
message
is
displayed
and
fuel
delivery
is
not
allowed.
The
list
of
periphearal
units
is
below.
Example:
Parameter
P10
‐
1,
serial
number
of
the
main
processor
unit
SN:
18
‐
00101
(see
picture)
4.1.15.
DISPENSER
CONTROL
MODE
(P12)
The
parameter
defines
how
the
dispenser
is
controlled.
Parameter
Meaning
Factory
Setting
12
=
0
Automatic
mode
with
remote
control
The
dispenser
is
remotely
controlled
by
a
computer
or
station
controller
via
a
data
line.
It
starts
fuel
delivery
only
when
an
authorization
command
from
the
the
control
system
(POS)
is
received.
The
authorization
command
includes
the
unit
price
of
fuel
for
each
refuelling,
preset
maximum
price
or
quantity,
and
the
product
number.
Fuel
delivery
will
not
start
at
zero
fuel
price,
zero
preset
amount/volume
or
if
the
product
number
does
not
match.
In
the
event
of
a
communication
failure,
the
dispenser
locks
up
with
error
E18.
Error
E18
always
occurs
if
no
communication
is
detected
for
more
than
3
seconds.
After
communication
is
established,
the
error
disappears
automatically.
0
12
=
3
Manual
mode
The
dispenser
is
completely
independent,
not
remote
controlled.
The
data
line
is
blocked.
Unit
fuel
prices
are
controlled
by
parameter
P03.
If
a
special
manual
mode
with
locking
after
delivery
or
a
mode
with
NOTE
The
yellow
service
remote
controllers
PDERT
‐
5S
are
used
by
authorized
service
personnel
of
TATSUNO
EUROPE
dispensers.
The
service
controllers
each
have
their
own
internal
identification
code,
which
is
written
into
the
memory
of
the
dispenser
counter
when
entering
the
service
mode.
Using
parameter
P09,
it
is
therefore
possible
to
find
out
who
entered
the
service
mode
of
the
counter
and
when,
i.e.,
to
identify
the
service
technician
and
the
time
of
the
service
intervention.
Parameter
Peripheral
unit
P10
‐
1
Serial
number
of
the
processor
unit
P10
‐
2
Serial
number
of
the
main
displaying
unit
(master
display)
P10
‐
3
Serial
number
of
the
auxiliary
displaying
unit
(slave
display)
P10
‐
4
Serial
number
of
the
unit
of
electromechanical
totalizers
P10
‐
5
Serial
number
of
the
heat
sensor
unit
(PDEINP)
P10
‐
6
Serial
number
of
the
mass
meter
M0
1111
P08
Sn
1
800101
P10
‐
1
INFO
19235
29
‐
00