3.2 Screens 

 

ALARM !! 

T1

 

ALARM !! 

T.Firep

 

 

Firplace   74

 o

 

30%   73

 o

Set temperature

fireplace sensor readout T3

Level of throttle opening

 

WAW   80

 o

 

68

 o

Upper temperature sensor T1 (if available)

Lower temperature sensor T2

 

It’s a stable state that is in order to change it one needs to press the CHOOSE button

10

PARAMETERS OF LEVEL  1

 

 

FUNCTION

 

45...85

o

C

70

 

o

C

 

Set temperature of fireplace kept by the regulator
.

 

30...60

o

C

50

 

o

C

 

Minimal temperature of fireplace at which the pump P3(CH) 
is activated.

 

20...85

o

C

50

 

o

C

 

Minimal temperature of fireplace at which the pump P1(WAW) 
turns on.

 

30...100

o

C

65

o

C

Maximal temperature of WAW accumulator. The exceeding
 turns off the supply pump   

 

30...100

o

C

50

o

C

Minimal temperature of WAW accumulator. The exceeding 
turns on the supply pump

 

1...10

o

C

2

o

C

Minimal difference between fireplace and WAW accumulator 
temperature needed for the pump operation P1 (WAW)

 

PARAMETERS OF LEVEL 2

 

 

 

 

0:00...23:45

6:00

 

Start of 1st time zone

 

0:00...23:45

8:00

 

 End of 1st time zone

 

:00...23:45

14:00

 

Start of 2nd time zone

 

0:00...23:45

17:30

 

End of 2nd time zone

 

0:00...23:45

20:00

 

Start of 3rd time zone

 

0:00...23:45   

22:30

 

End of 3rd time zone

 

PARAMETERS OF LEVEL  3

 

 

 

10...60secs

20secs

 

Rest time of the throttle between successive change of its position 

 

0...100%

0%

 

Position of the throttle in the power-off state
(0%-full closing, 100%-full opening)

 

 

1...30mins

4mins

 

Pause time of CH pump in cyclical mode. After the time the pump
turns on for 45 secs.

 

1...2

1

 

Kind of supply for the WAW accumulator

 

1

 

Temperature sensor T2 (down) controls the supply of WAW

 

2

 

Temperature sensors T1 (up) and T2 (down) control 
the supply of WAW accumulator 

 

75...95

o

C

85

 

o

C

 

Fireplace temperature at which alarm turns on.

 

5...25

o

C

10

 

o

C

 

Decreasing fireplace temperature in relation to set temperature
at whose exceeding the countdown of 30mins begins up to the 
switch-off of  fireplace  (stop condition at Firp.MOD=AUTO)

 

1...6

1

 

Switch-on of the relay CONTROL if

 

1

 

fireplace temperature is higher than „T.CH.ON”

 

2

 

 fireplace temperature is higher than„T.WAW.ON”

 

3

 

 

4

 

„T.minWAW”

 

5

 

„T.maxWAW”

 

6

 

fireplace temperature is higher than 

 

 „T.Alarm”

 

NAME

T.Firep

T.CH.ON

T.WAW.ON

T.maxWAW

T.min WAW

DeltaWAW

Zone1 fr
Zone1 to
Zone2 fr

0

Zone2 to
Zone3 fr
Zone3 to

Ti.Pause

ModeOFF

Ti.EndCH

ctrlWAW

T.Alarm

T.FirOFF

RelaySTR

RANGE

FACTORY
SETTING

 

 

 

 

 

P

ARAMETERS OF LEVEL 4

 

 

 

 

0....1

0

 

Setting the value of “1” causes the recall of all parameters to 
their factory pre-sets and restart the regulator

 

 

 

 

 

Reset

FUNCTION

NAME

RANGE

FACTORY
SETTING

FUNCTION

NAME

RANGE

FACTORY
SETTING

FUNCTION

NAME

RANGE

FACTORY
SETTING

WAW temperature measured by T2 sensor is higher
than “T.minWAW”
WAW temperature measured by T1 sensor is higher than

WAW temperature measured by T2 sensor is higher than

Alarm screens 

is not seen till the following emergency situation takes place:

1. Damage of sensor T1 (upper one of WAW). “T1” shows up. The alarm doesn’t work if the 

sensor is not installed.

2. Damage of sensor T2 (lower one of WAW). “T2” shows up.
3. Damage of sensor T3 (of fireplace). “T3” shows up.
4. The exceeding of  the

 

acceptable temperature of fireplace /”

T.Firep

”/ defined by 

    the “

T.Alarm

” parameter

Emergency situation is accompanied by a broken sound alarm that can be turned off by pressing the 
CONFIRM  button.
In emergency of temperature exceeding the pump CH turns on to cool off fireplace.

Screen  of  fireplace  water  jacket  temperature  measurement 

shows  the  actual  temperature  of 

fireplace and the level of throttle opening.

It’s a stable state that is in order to change it one need to press the CHOOSE button
During appearing this screen one can change the set temperature of a fireplace (”

T.Firep

” parameter). 

After pressing the CONFIRM button (5) the set temperature blinnks whose value can be altered with 
the buttons “+” (2) or “-” (4). To confirm the changes one needs to press CONFIRM once more. If the 
manual mode is set (Firp.MOD=MAN)one can manually control the throttle- the button “+” (2) 
causes the opening of the  throttle  (one step 10%) and the button “-” (4) causes its closing. 

Screen of WAW temperature 

shows the actual temperature in the upper and lower part of the WAW 

accumulator.

Summary of Contents for RT-08P

Page 1: ...control a throttle drive 1 5V 500mA DC o Number of water temperature sensors 3 KTY81 0 100 C o Temp measurement precision 2 C o Temp measurement resolution 0 5 C Number of time zones 4 Zak ad elektro...

Page 2: ...water accumulator WAW The pump operates if fireplace temperature both exceeds the ONWAW value and is higher than the WAW accumulator temperature T2 by the DeltaWAW parameter see LEVELPARAMETERS1 The t...

Page 3: ...r house usage and the like Part 1 General requirements PN EN 55022 2000 Electromagnetic compatibility EMC IT devices Characteristics of radioelectric noises Acceptable levels and measurement methods C...

Page 4: ...Burnt fuses arenot subject towarranty replacement Register No GIOS E 0002240WZ Worn out electronic and electric devices must be transfered to the utilization collection place where will be accepted fo...

Page 5: ...ymoreprecisely seePARAMETERSofLEVEL3 There are elements on the control panel fig 2 In the turn off state only the orange lamp 7 lights indicatingthe standby mode The turn on of the regulator follows b...

Page 6: ...g the throttle position in power off state parameter of level 3 Press repeatedly CHOOSE button till the Menu 0 parameter setting screen appears CONFIRM button 0 starts blinking threefold button 3 blin...

Page 7: ...n of the relay CONTROL if 1 fireplace temperature is higher than T CH ON 2 fireplace temperature is higher than T WAW ON 3 4 T minWAW 5 T maxWAW 6 fireplace temperature is higher than T Alarm NAME T F...

Page 8: ...ing the turn offstateoffireplace OFF Settingthethrottleatrestposition definedbythe ModeOFF parameter Greenstatuslamp 7 doesn tlight MAN Automaticcontrolblocked onlymanualcontrolisavailable Greenstatus...

Reviews: