7
3.2 Screens
ALARM !!
T1
ALARM !!
T.Firep
Firplace 74
o
30% 73
o
Set temperature
fireplace sensor readout T3
Level of throttle opening
WAW 80
o
68
o
Upper temperature sensor T1 (if available)
Lower temperature sensor T2
It’s a stable state that is in order to change it one needs to press the CHOOSE button
10
PARAMETERS OF LEVEL 1
FUNCTION
45...85
o
C
70
o
C
Set temperature of fireplace kept by the regulator
.
30...60
o
C
50
o
C
Minimal temperature of fireplace at which the pump P3(CH)
is activated.
20...85
o
C
50
o
C
Minimal temperature of fireplace at which the pump P1(WAW)
turns on.
30...100
o
C
65
o
C
Maximal temperature of WAW accumulator. The exceeding
turns off the supply pump
30...100
o
C
50
o
C
Minimal temperature of WAW accumulator. The exceeding
turns on the supply pump
1...10
o
C
2
o
C
Minimal difference between fireplace and WAW accumulator
temperature needed for the pump operation P1 (WAW)
PARAMETERS OF LEVEL 2
0:00...23:45
6:00
Start of 1st time zone
0:00...23:45
8:00
End of 1st time zone
:00...23:45
14:00
Start of 2nd time zone
0:00...23:45
17:30
End of 2nd time zone
0:00...23:45
20:00
Start of 3rd time zone
0:00...23:45
22:30
End of 3rd time zone
PARAMETERS OF LEVEL 3
10...60secs
20secs
Rest time of the throttle between successive change of its position
0...100%
0%
Position of the throttle in the power-off state
(0%-full closing, 100%-full opening)
1...30mins
4mins
Pause time of CH pump in cyclical mode. After the time the pump
turns on for 45 secs.
1...2
1
Kind of supply for the WAW accumulator
1
Temperature sensor T2 (down) controls the supply of WAW
2
Temperature sensors T1 (up) and T2 (down) control
the supply of WAW accumulator
75...95
o
C
85
o
C
Fireplace temperature at which alarm turns on.
5...25
o
C
10
o
C
Decreasing fireplace temperature in relation to set temperature
at whose exceeding the countdown of 30mins begins up to the
switch-off of fireplace (stop condition at Firp.MOD=AUTO)
1...6
1
Switch-on of the relay CONTROL if
1
fireplace temperature is higher than „T.CH.ON”
2
fireplace temperature is higher than„T.WAW.ON”
3
4
„T.minWAW”
5
„T.maxWAW”
6
fireplace temperature is higher than
„T.Alarm”
NAME
T.Firep
T.CH.ON
T.WAW.ON
T.maxWAW
T.min WAW
DeltaWAW
Zone1 fr
Zone1 to
Zone2 fr
0
Zone2 to
Zone3 fr
Zone3 to
Ti.Pause
ModeOFF
Ti.EndCH
ctrlWAW
T.Alarm
T.FirOFF
RelaySTR
RANGE
FACTORY
SETTING
P
ARAMETERS OF LEVEL 4
0....1
0
Setting the value of “1” causes the recall of all parameters to
their factory pre-sets and restart the regulator
Reset
FUNCTION
NAME
RANGE
FACTORY
SETTING
FUNCTION
NAME
RANGE
FACTORY
SETTING
FUNCTION
NAME
RANGE
FACTORY
SETTING
WAW temperature measured by T2 sensor is higher
than “T.minWAW”
WAW temperature measured by T1 sensor is higher than
WAW temperature measured by T2 sensor is higher than
Alarm screens
is not seen till the following emergency situation takes place:
1. Damage of sensor T1 (upper one of WAW). “T1” shows up. The alarm doesn’t work if the
sensor is not installed.
2. Damage of sensor T2 (lower one of WAW). “T2” shows up.
3. Damage of sensor T3 (of fireplace). “T3” shows up.
4. The exceeding of the
acceptable temperature of fireplace /”
T.Firep
”/ defined by
the “
T.Alarm
” parameter
Emergency situation is accompanied by a broken sound alarm that can be turned off by pressing the
CONFIRM button.
In emergency of temperature exceeding the pump CH turns on to cool off fireplace.
Screen of fireplace water jacket temperature measurement
shows the actual temperature of
fireplace and the level of throttle opening.
It’s a stable state that is in order to change it one need to press the CHOOSE button
During appearing this screen one can change the set temperature of a fireplace (”
T.Firep
” parameter).
After pressing the CONFIRM button (5) the set temperature blinnks whose value can be altered with
the buttons “+” (2) or “-” (4). To confirm the changes one needs to press CONFIRM once more. If the
manual mode is set (Firp.MOD=MAN)one can manually control the throttle- the button “+” (2)
causes the opening of the throttle (one step 10%) and the button “-” (4) causes its closing.
Screen of WAW temperature
shows the actual temperature in the upper and lower part of the WAW
accumulator.