Zakład elektroniczny TATAREK Jerzy Tatarek
USER MANUAL
1
KOMINEK LUX (RT-08P)
REGULATOR OF HEATING SYSTEM
WITH A FIREPLACE CONTROLLED
BY AIR THROTTLE
16
RT08P/2008/v.1.8 ANG
1.Basic technical parameters:
Power
230V/50Hz
Power consumption without load
5W
Max connection power
750W
o
Operation conditions
0
¸
50 C, humidity 10
¸
90%
(No condensation)
Housing protection class
IP41
Fuse
6,3A/250V
Number of outputs to control pumps
3 * 250W/230V/50Hz
Number of nonvoltage outputs
1
Number of outputs to control a throttle drive
1 * 5V/500mA/DC
o
Number of water temperature sensors
3 * KTY81 (0...+100 C )
o
Temp. measurement precision
2 C
o
Temp. measurement resolution
0,5 C
Number of time zones
4
Zakład elektroniczny TATAREK Jerzy Tatarek
50-559 Wroclaw, 75 Swieradowska st.
ph. (071) 367-21-67, 373-14-88, fax 373-14-58; Tax index number 899-020-21-48;
Bank account: BZ WBK S.A. WROCLAW 6910901522-0000-0000-5201-9335
www.tatarek.com.pl.; E-mail: [email protected]
The regulator controls heating system based on a water jacket fireplace that is a heat source, in which
combustion process is controlled by air throttle. The heat receivers are: Warm Applicable Water
accumulator (WAW) and Central Heating system (CH).