5.1.4.4 Replacing of pump
Picture 12: Pump
Remove
•
Unlock battery compartment by removing the screws from the
locking system.
•
Open the battery compartment.
•
Lower the brush drive unit to cleaning position without tool
underneath.
•
Unscrew brush housing fixation screws.
•
Remove the brush housing to get access to the pump.
•
Disconnect the pump wires.
•
Unscrew hose clamps on both sides of the pump.
•
Remove the fresh water hoses from the pump.
Picture 13: Pump
•
Thread out pump from pump holder.
Mount
•
Position new pump into pump holder.
Ensure that the pump is build in according to the water flow. The
arrow on the pump indicates the water flow direction.
•
Connect fresh water hoses on the pump with the clamps.
•
Connect wires to the pumps.
•
Mount the brush housing.