5.1.6 Brush drive unit
5.1.6.1 Replacing of brush drive unit
Picture 15: Brush drive replacing
Remove
•
Unlock battery compartment by removing screws from locking
system.
•
Open battery compartment.
•
Put the brush drive unit in cleaning position.
•
Unscrew brush housing fixation screws.
•
Remove the brush housing from the brush drive unit.
•
Disconnect pump wiring.
•
Disconnect the fresh water hose from the pump.
•
Disconnect the brush motor wires from power electronics.
•
Remove self locking nuts (M8) on LH and RH from the bolts,
holding brush drive unit to the cradle.
•
Remove self locking nut (M6) at eccentric disc at the RH.
•
Remove the eccentric disc.
•
Remove the bolt and eccentric shaft.
Make sure that you hold the brush drive unit firmly.
•
Pivot the complete brush drive unit out.
Mount
•
Position the brush drive unit to the cradles.
•
Position the bolt and the eccentric shaft.
•
Position the eccentric disc.
Adjustment
Default setting:
Eccentric disc (07/122): Position 4
Eccentric shaft (07/110): Position 4