After the infrared thermometer is used for a period of time, dust will be accumulated on 
the lens. Clean ball can be used to blow off dust on the surface or clean cotton swab is 
used to clean the lens surface with a little water. 

 

Shell cleaning: 

A soft cloth stained with neutral cleaning solution can be used to wipe the thermometer 
shell. 

 

Replace the battery: 

When the power indicator on the LCD has no level, please replace the battery in time. In 
order to protect the environment, please dispose of the replaced batteries properly. 

 

When the instrument is not used for a long time, please take out the battery and store it. 

 

If the instrument foils, it should be repaired after being confirmed by the manufacturer 

or dealer. The user should provide the text description and packing list of the failure 
phenomenon. The packaging of the instrument should be well buffered and protected. 
 

Summary of Contents for TA603A

Page 1: ...loped high performance and high quality instrument which uses ARM single chip computer to collect and process data The instrument has the functions of emissivity adjustment maximum value minimum value overage value temperature difference value high and low temperature alarm setting It has the advantages of high measurement accuracy fast response speed simple operation and reliable use It can be wi...

Page 2: ... Bluetooth symbol 14 Symbols for manual measurement and continuous measurement 15 Data holding symbol 16 Multi function display symbol 17 Confirm button 18 Downward adjustment button 19 Mode menu button Panel Introduction Operation instructions After installing the battery press the measurement switch after the full screen display for 1 second you can directly press the measurement switch for test...

Page 3: ...e the difference between the measured value and the reference value will be displayed AVG When the AVG mode is selected to flash press the OK button to confirm when testing the measured values will be displayed after averaging STO When the STO mode is selected to flash press the OK key to confirm and 001 will be displayed At this time press the measurement key to measure the data and hold a value ...

Page 4: ... 32 1000 C 0 1 C 1000 above 1 C Response time and wavelength Less than 500ms 8 14um Emissivity 0 1 1 00 adjustable step length 0 01 Measuring object distance ratio 50 1 TA603A B C 80 1 TA603D E Laser aiming Less than 1MW 650nm laser grade II C Fconversion V Screen display mode VA Color screen Backlight display 4 Over range prompt HI or 10 Power Supply 9V 6F22 Working environment temperature 0 C 50...

Page 5: ...Emery Ceramics 0 90 0 95 Polished 0 30 Oxidized 0 50 Clay 0 95 Chromium 0 02 Copper Polished 0 03 Concrete 0 95 Polished 0 05 0 10 Cloth 0 95 Oxidation 0 40 0 80 Glass 0 85 Gold 0 01 0 10 Gravel 0 95 Nickel chromium iron alloy Oxidation 0 70 0 95 Gypsum 0 85 0 95 Frosted 0 30 0 60 Electropolishing 035 Ice 0 95 Iron Oxidation 0 50 0 90 Paint Colorless transparent 0 92 Non oxidation 0 05 0 20 Dark b...

Page 6: ... of the field of view measured by the instrument and it is better to make the target size more than twice of the field of view spot The influence of emissivity on temperature measurement Emissivity represents the thermal radiation ability of the object surface Due to the different material and surface state of the object its ability to radiate infrared energy is different In order to compensate th...

Page 7: ...l Replace the battery When the power indicator on the LCD has no level please replace the battery in time In order to protect the environment please dispose of the replaced batteries properly When the instrument is not used for a long time please take out the battery and store it If the instrument foils it should be repaired after being confirmed by the manufacturer or dealer The user should provi...