9 – Specifications : Messages and troubleshooting
TASCAM DM-4800
User’s Manual
127
✔
Confirm LIST Auto Detect?
Press ENTER to confirm,
or a cursor key to cancel.
Confirming the auto-detection of machine control list.
✔
Confirm TRA Auto Detect?
Press ENTER to confirm,
or a cursor key to cancel.
Confirming the auto-detection of transport control mapping.
✔
Copy from Ch2 Automation configuration
Confirmation when copying automation configuration.
●
Copy Module parameters to CHn.
Notification that a parameter copy operation between modules has been carried out
correctly.
✔
Copy Module parameters to CHn?
Press ENTER to confirm,
or a cursor key to cancel.
Confirmation that parameters are to be copied to another module.
✔
Copy parameters
within Module?
Press ENTER to confirm
or a cursor key to canvel.
Confirmation when performing a parameter copy operation within the same module.
✔
Copy to xxxx fader level
Press ENTER to confirm,
or a cursor key to cancel
Confirmation when copying fader levels. xxxx may be ALL, ALL MASTER, Aux 1-8, groups
of 8 busses, or groups of 8 channels.
●
Copy was completed.
Popup message on completion of copy operation.
●
Copying project.
Do not remove the CF card.
Shown while a project is being copied on the CF card.
✔
Create project?
Press ENTER to confirm,
or a cursor key to cancel.
Confirming creation of a project.
●
Creating project.
Do not remove the CF card.
Warning not to remove CF card during project completion.
✖
Current Data initialized.
Fs has changed.
Mixer will reboot.
Press ENTER to confirm,
or a cursor key to cancel.
Notice to restart the DM-4800 following a change of reinitialization and sampling
frequency.
✔
Current project is protected.
Can't STORE current project.
ENTER key : Shut down
CURSOR key : Cancel
An attempt has been made to shut down the DM-4800 while the current project’s
version on card is protected (meaning that it cannot be saved).
●
Data change was applied.
Date and time have been changed.
●
Data has not been changed.
Date and time have not been changed.
●
Deleting project.
Do not remove the CF card.
Shown while a project is being deleted from the CF card.
✖
Device is not active.
A device selected for transport control is not active.
✖
Digital In1: Error
Not audio signal
Press ENTER to continue.
The DIGITAL IN audio source is not providing digital audio data.
✖
Digital In1: Error
Not audio signal
Source Fs unlocked
Press ENTER to continue.
The DIGITAL IN clock source is not providing digital audio data, and the sync clock is now
unlocked.
✖
Digital In1: Error
Source Fs unlocked
Press ENTER to continue.
The DIGITAL IN clock source has experienced an error, and the sync clock is now
unlocked.
Action
Message
Meaning
Table 9.1: Popup messages (continued)