background image

10.6 : SECUR ET - VEB EYEBOLT

The Tannoy

 

Power V™

 loudspeaker can be flown with high quality

VEB M10 eyebolts with collar to BS4278:1984. The loudspeakers
are equipped with internal steel braces, which also double as the
flying points, and accept VEB M10 eyebolts.

To install the VEB M10 eyebolts remove the original M10 counter
sunk screws from the locations you wish to install the VEB M10
eyebolts. Then replace these counter sunk M10 screws with the VEB
M10 eyebolts. The M10 insert on the rear of the cabinet also accepts
a VEB M10 eyebolt and should 

only

 be used for tilting the loudspeaker

to the desired angle.

Important: It is imperative for safety reasons that two
eyebolts linked to two independently fixed straps are
used per cabinet. VEB eyebolts should be installed 
into the relative sides of the cabinet, and should NEVER
be installed on the top of the cabinet. Never suspend

one enclosure from another to form a line array or cluster using
these fittings.

The correct method is shown in figure 2.
Never attempt to use formed eyebolts i.e. formed from a steel
rod and bent into an eye.

Only use the outer fixing points on the top and sides of the

Power V™

 cabinet for fixing eyebolts. The inner two fixing points on

each side of the cabinet are for dedicated bracketry (VMY) only.
.

p  r  o  f  e  s  s  i  o  n  a  l

p  r  o  f  e  s  s  i  o  n  a  l

p  r  o  f  e  s  s  i  o  n  a  l

p  r  o  f  e  s  s  i  o  n  a  l

FIG 2.

FIG 1.

19

Summary of Contents for V12HP

Page 1: ...POWER V6 POWER V8 POWER V12 POWER V12HP POWER V15 POWER VS10BP POWER VS15BP Owners Manual...

Page 2: ...6 0 EQUALISATION 7 0 ARRAYING 8 0 DIMENSIONS 9 0 TECHNICAL SPECIFICATIONS 10 0 RIGGING 10 1 SECUR ET V6Y yoke bracket 10 2 SECUR ET V8Y yoke bracket 10 3 SECUR ET VMY yoke bracket 10 4 SECUR ET V15Y V...

Page 3: ...ally or has been dropped SAFETY WARNING Permanent disconnection from the mains supply is to be achieved by removing the supplied cord connector from the back of the unit SAFETY WARNING Do not remove a...

Page 4: ...2 2 No 60065 03 EMC This equipment has been designed to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protect...

Page 5: ...has been sustained in transit notify your dealer immediately 3 1 PRELIMINARY RECOMMENDATION A word of warning on high sound levels these speakers are capable of generating high output levels over sust...

Page 6: ...signs which include system specific EQ and protection circuitry without the need for external amplification For room equalization delay and other commissioning or setup functions we recommend you use...

Page 7: ...nnection there are two signal conductors and a shield The shield is normally referenced to ground at one or both ends Many times the shield is lifted at one end usually at the input to eliminate groun...

Page 8: ...nets with the 30 degree angled rear panels together minimal dispersion pattern overlap is achieved guaranteeing an extraordinarily smooth transition In many applications the 90 degree 75 degree on the...

Page 9: ...0 11 54 154 0 6 01 AVIS OUVRIR RAIN OR MOISTURE RISQUE DE CHOC ELECTRIQUE NE PAS SHOCK DO NOT EXPOSE THIS EQUIPMENT TO TO REDUCE THE RISK OF FIRE OR ELECTRIC WARNING COMPLIES WITH PART 15 OF THE FCC...

Page 10: ...HE MANUAL CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS AND THIS CLASS D DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THE OUVRIR RAIN OR MOISTURE FUSE T10AL 250V REPLACE ONLY WITH TANNOY PART 3461 0...

Page 11: ...80Hz 38kHz 120dB average 126dB peak 90 Degrees Conical 1 x 300mm 12 Dual Concentric 8 2 averaged 1kHz to 10kHz 8 8 averaged 1kHz to 10kHz 2nd Harmonic 3rd Harmonic 0 56 0 23 2 36 1 88 2 68 0 08 2nd H...

Page 12: ...protection recovery Inrush current limiting 1x Limit LED 1x Signal LED 1x Power LED one Class D Locking Neutrik Powercon Automatic 115 230V 45 65Hz High current high freq switch mode 90 typical 100V...

Page 13: ...using the accessory kits supplied and in strict compliance with the user manual The use of other accessories or non approved methods of assembly may result in an unsafe hardware system by reducing th...

Page 14: ...made depending on the application and the coverage pattern required see figures 1 2 Using the VCS ceiling saddle the resulting cluster can be attached to the ceiling VCB4 The VCB4 cluster bar availabl...

Page 15: ...DESCRIPTION Cluster Bar Washer M10 Plain Screw M10x40 Button Head M10 Nyloc Nut Blanking Plug QUANTITY 1 2 2 2 2 Contents of VCB2 1 2 3 4 5 DESCRIPTION Cluster Bar Washer M10 Plain Screw M10x40 Butto...

Page 16: ...er on Assembly View Fig 3 Description Quantity 1 Hanging Bracket 2 2 Cross Member 1 3 Pivot Stud 2 4 M10 Plain Washer 2 5 M8 Spring Washer 2 6 M10 Spring Washer 4 7 M10 x 30mm Screw 2 8 M8 x 20mm Scre...

Page 17: ...17 10 4 SECUR ET V15Y V12Y V15Y V12Y...

Page 18: ...fixing obtained There are also two holes either side of the fixing beam to allow the speaker cable the pass through the wall plate and along the fixing beam to the terminal panel resulting in a more d...

Page 19: ...e desired angle Important It is imperative for safety reasons that two eyebolts linked to two independently fixed straps are used per cabinet VEB eyebolts should be installed into the relative sides o...

Page 20: ...available in both black and white finishes and is to be used in conjunction with the VMY and a length of M10 threaded rod not supplied by Tannoy Limited The VCS ceiling saddle allows the Tannoy Power...

Page 21: ...ne Kit 2522 PowerV15BP 7900 0596 Driver Kit 3813 7900 0600 Recone Kit 3813 PowerV HARDWARE 8001 2780 VMY Secur ET Yoke Adjustable Black 8001 2790 VMY Secur ET Yoke Adjustable White 8001 2800 VMB Secur...

Page 22: ...s is are manufactured in UK by Tannoy Ltd of Rosehall Industrial Estate Coatbridge Scotland ML5 4TF The following equipment is marked with the CE label and conform s to the protection requirements of...

Page 23: ...14 0 NOTES...

Page 24: ...NOTES...

Page 25: ...NOTES...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...ct specification is subject to change Tannoy United Kingdom T 44 0 1236 420199 F 44 0 1236 428230 E enquiries tannoy com Tannoy North America T 519 745 1158 F 519 745 2364 E inquiries tannoyna com Tan...

Reviews: