INSTALLATION INSTRUCTIONS

1

THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord provided with a green or green and yellow core
which must be connected to the protective earthing terminal of the detachable Neutrik 'Powercon' type NEC3FCA 
connector (Tannoy part number 3461 0919 as supplied with the equipment. The other end of the green or green and 
yellow conductor must be connected to the earthing pin of a suitable mains plug or the earthing terminal of the installation.
The cord must be of maximum length 7.5 meters, rated SJ, SJT, or SJE, 10A minimum and be marked VW-1.

2

The electrical power connection to this product is only to be made via a detachable Neutrik 'Powercon' type NEC3FCA 
connector (Tannoy part number 3461 0919) as supplied with the equipment.  Wiring to this connector must only be made
by suitably qualified personnel and must comply with all local requirements.

3

Do not install this equipment in an enclosed space. Do not limit free ventilation and movement of air around the back 
panel. Ensure that there is at least 100mm (4") of space around all sides of the product for ventilation.

4

Only use attachments and accessories approved by or specified by Tannoy.

FOR CUSTOMERS IN EUROPE

This product complies with both the LVD (electrical safety) 73/23/EEC and EMC (electromagnetic compatibility) 89/336/EEC
directives issues by the commission of the European community.

Compliance with these directives implies conformity with the following European standards:

EN60065

Product safety

EN55103-1

EMC emissions

EN55103-2

EMC immunity

This product is intended for the following electromagnetic environments: E2; E3 & E4. Environment E1 (domestic) is specifically
excluded.

FOR CUSTOMERS IN THE USA & CANADA

This product has been tested for electrical safety and complies with:

UL60065 7th edition
CA /CSA C22.2 No.60065-03

EMC

This equipment has been designed to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment.

Industry Canada Class A emission compliance statement: This Class B digital apparatus complies with Canadian ICES-003.
Avis de conformite' a' la re'glementation d'Industrie Canada. Cet appareil nume'rique de classe A est conforme a' la norme
ICES-003.

2.0: INTRODUCTION

Power V™ is a range of active sound reinforcement loudspeakers equipped with the Tannoy Dual Concentric™, point source,
constant directivity drive unit technology. By combining the ‘Dual’ with a sophisticated amplifier package integrated within the
speaker cabinet, Power V™ is aimed at installation applications where uncompromised sound quality and flexibility is essential.
In order to satisfy a wide scope of fixed or on the road sound reinforcement applications there are five full range models and
two subwoofers in the Power V™ range; Power V6, Power V8, Power V12, Power V12HP and Power V15; along with the
subwoofers - Power VS10 BP and Power VS15 BP.

The location of the high frequency drive unit, in the throat of the low frequency driver, ensures that the driver delivers constant
directivity and unparalleled linearity from a true point source.

The spherical wave front delivered presents an even dispersion in both horizontal and vertical planes, providing exceptional
off-axis performance and an even response throughout a wide listening area. Overcoming the time alignment problems inherent
in a discretespeaker design the constant directivity characteristics of the ‘Dual’ exhibits better harmonic alignment, delivering
a more natural sound with superb tonal balance and greater intelligibility. This highly integrated driver design approach provides
a constant time delay over the frequency spectrum ensuring enhanced transient performance and sound quality.

Summary of Contents for V12HP

Page 1: ...POWER V6 POWER V8 POWER V12 POWER V12HP POWER V15 POWER VS10BP POWER VS15BP Owners Manual...

Page 2: ...6 0 EQUALISATION 7 0 ARRAYING 8 0 DIMENSIONS 9 0 TECHNICAL SPECIFICATIONS 10 0 RIGGING 10 1 SECUR ET V6Y yoke bracket 10 2 SECUR ET V8Y yoke bracket 10 3 SECUR ET VMY yoke bracket 10 4 SECUR ET V15Y V...

Page 3: ...ally or has been dropped SAFETY WARNING Permanent disconnection from the mains supply is to be achieved by removing the supplied cord connector from the back of the unit SAFETY WARNING Do not remove a...

Page 4: ...2 2 No 60065 03 EMC This equipment has been designed to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protect...

Page 5: ...has been sustained in transit notify your dealer immediately 3 1 PRELIMINARY RECOMMENDATION A word of warning on high sound levels these speakers are capable of generating high output levels over sust...

Page 6: ...signs which include system specific EQ and protection circuitry without the need for external amplification For room equalization delay and other commissioning or setup functions we recommend you use...

Page 7: ...nnection there are two signal conductors and a shield The shield is normally referenced to ground at one or both ends Many times the shield is lifted at one end usually at the input to eliminate groun...

Page 8: ...nets with the 30 degree angled rear panels together minimal dispersion pattern overlap is achieved guaranteeing an extraordinarily smooth transition In many applications the 90 degree 75 degree on the...

Page 9: ...0 11 54 154 0 6 01 AVIS OUVRIR RAIN OR MOISTURE RISQUE DE CHOC ELECTRIQUE NE PAS SHOCK DO NOT EXPOSE THIS EQUIPMENT TO TO REDUCE THE RISK OF FIRE OR ELECTRIC WARNING COMPLIES WITH PART 15 OF THE FCC...

Page 10: ...HE MANUAL CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS AND THIS CLASS D DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THE OUVRIR RAIN OR MOISTURE FUSE T10AL 250V REPLACE ONLY WITH TANNOY PART 3461 0...

Page 11: ...80Hz 38kHz 120dB average 126dB peak 90 Degrees Conical 1 x 300mm 12 Dual Concentric 8 2 averaged 1kHz to 10kHz 8 8 averaged 1kHz to 10kHz 2nd Harmonic 3rd Harmonic 0 56 0 23 2 36 1 88 2 68 0 08 2nd H...

Page 12: ...protection recovery Inrush current limiting 1x Limit LED 1x Signal LED 1x Power LED one Class D Locking Neutrik Powercon Automatic 115 230V 45 65Hz High current high freq switch mode 90 typical 100V...

Page 13: ...using the accessory kits supplied and in strict compliance with the user manual The use of other accessories or non approved methods of assembly may result in an unsafe hardware system by reducing th...

Page 14: ...made depending on the application and the coverage pattern required see figures 1 2 Using the VCS ceiling saddle the resulting cluster can be attached to the ceiling VCB4 The VCB4 cluster bar availabl...

Page 15: ...DESCRIPTION Cluster Bar Washer M10 Plain Screw M10x40 Button Head M10 Nyloc Nut Blanking Plug QUANTITY 1 2 2 2 2 Contents of VCB2 1 2 3 4 5 DESCRIPTION Cluster Bar Washer M10 Plain Screw M10x40 Butto...

Page 16: ...er on Assembly View Fig 3 Description Quantity 1 Hanging Bracket 2 2 Cross Member 1 3 Pivot Stud 2 4 M10 Plain Washer 2 5 M8 Spring Washer 2 6 M10 Spring Washer 4 7 M10 x 30mm Screw 2 8 M8 x 20mm Scre...

Page 17: ...17 10 4 SECUR ET V15Y V12Y V15Y V12Y...

Page 18: ...fixing obtained There are also two holes either side of the fixing beam to allow the speaker cable the pass through the wall plate and along the fixing beam to the terminal panel resulting in a more d...

Page 19: ...e desired angle Important It is imperative for safety reasons that two eyebolts linked to two independently fixed straps are used per cabinet VEB eyebolts should be installed into the relative sides o...

Page 20: ...available in both black and white finishes and is to be used in conjunction with the VMY and a length of M10 threaded rod not supplied by Tannoy Limited The VCS ceiling saddle allows the Tannoy Power...

Page 21: ...ne Kit 2522 PowerV15BP 7900 0596 Driver Kit 3813 7900 0600 Recone Kit 3813 PowerV HARDWARE 8001 2780 VMY Secur ET Yoke Adjustable Black 8001 2790 VMY Secur ET Yoke Adjustable White 8001 2800 VMB Secur...

Page 22: ...s is are manufactured in UK by Tannoy Ltd of Rosehall Industrial Estate Coatbridge Scotland ML5 4TF The following equipment is marked with the CE label and conform s to the protection requirements of...

Page 23: ...14 0 NOTES...

Page 24: ...NOTES...

Page 25: ...NOTES...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...ct specification is subject to change Tannoy United Kingdom T 44 0 1236 420199 F 44 0 1236 428230 E enquiries tannoy com Tannoy North America T 519 745 1158 F 519 745 2364 E inquiries tannoyna com Tan...

Reviews: