1.0: IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.

8

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers)

that produce heat.

9

Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one 

wider than the other. A grounding type plug had two blades and a third grounding prong. The wide blade or the third

prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement

of the obsolete outlet.

10

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the point

where they exit from the apparatus.

11

Only use attachments / accessories specified by the manufacturer.

12

Use only with the cart, tripod, bracket or table specified by the manufacturer, or sold with the apparatus. When a cart

is used, use caution when moving the cart / apparatus combination to avoid injury from tip-over.

13

Unplug this apparatus during lightening storms or when unused for long periods of time.

14

Refer all servicing to qualified service personnel. Service is required when the apparatus has been damaged in any

way, such as power-supply cord or plug damaged, liquid has been spilled or objects have fallen into the apparatus, 

this apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

SAFETY WARNING

Permanent disconnection from the mains supply is to be achieved by removing the supplied cord connector from the back of

the unit.

SAFETY WARNING

Do not remove any covers, loosen any fixings or allow items to enter any aperture.

SAFETY WARNING

Objects filled with liquids should not be placed on this apparatus.

SAFETY WARNING

Replace the mains fuse only with the same T10A HBC type supplied by Tannoy under part number 34610919

SAFETY WARNING

The rear heatsink on this product gets hot. Avoid direct skin contact during operation and for at least 5 minutes after power

has been isolated.

AVERTISSEMENT DE SECURITE

Pour déconnecter l'appareil de l'alimentation principale de façon permanente, débranchez le connecteur du câble fourni à

l'arrière de l'appareil.

AVERTISSEMENT DE SECURITE

Ne retirez pas les couvercles, ne desserrez pas les fixations et ne laissez aucune pièce s'introduire dans les ouvertures.

AVERTISSEMENT DE SECURITE

Ne placez pas d'objets contenant du liquide à proximité de l'appareil.

AVERTISSEMENT DE SECURITE

Ne remplacez le fusible de réseau principal que par un fusible T10A HBC du même type fourni par Tannoy sous la référence

34610919.

AVERTISSEMENT DE SECURITE

Le radiateur arrière de cet appareil devient chaud. Evitez tout contact direct avec la peau pendant le fonctionnement et au

moins 5 minutes après la mise hors tension de l'appareil.

The lightning flash with an arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.

Summary of Contents for V12HP

Page 1: ...POWER V6 POWER V8 POWER V12 POWER V12HP POWER V15 POWER VS10BP POWER VS15BP Owners Manual...

Page 2: ...6 0 EQUALISATION 7 0 ARRAYING 8 0 DIMENSIONS 9 0 TECHNICAL SPECIFICATIONS 10 0 RIGGING 10 1 SECUR ET V6Y yoke bracket 10 2 SECUR ET V8Y yoke bracket 10 3 SECUR ET VMY yoke bracket 10 4 SECUR ET V15Y V...

Page 3: ...ally or has been dropped SAFETY WARNING Permanent disconnection from the mains supply is to be achieved by removing the supplied cord connector from the back of the unit SAFETY WARNING Do not remove a...

Page 4: ...2 2 No 60065 03 EMC This equipment has been designed to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protect...

Page 5: ...has been sustained in transit notify your dealer immediately 3 1 PRELIMINARY RECOMMENDATION A word of warning on high sound levels these speakers are capable of generating high output levels over sust...

Page 6: ...signs which include system specific EQ and protection circuitry without the need for external amplification For room equalization delay and other commissioning or setup functions we recommend you use...

Page 7: ...nnection there are two signal conductors and a shield The shield is normally referenced to ground at one or both ends Many times the shield is lifted at one end usually at the input to eliminate groun...

Page 8: ...nets with the 30 degree angled rear panels together minimal dispersion pattern overlap is achieved guaranteeing an extraordinarily smooth transition In many applications the 90 degree 75 degree on the...

Page 9: ...0 11 54 154 0 6 01 AVIS OUVRIR RAIN OR MOISTURE RISQUE DE CHOC ELECTRIQUE NE PAS SHOCK DO NOT EXPOSE THIS EQUIPMENT TO TO REDUCE THE RISK OF FIRE OR ELECTRIC WARNING COMPLIES WITH PART 15 OF THE FCC...

Page 10: ...HE MANUAL CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS AND THIS CLASS D DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THE OUVRIR RAIN OR MOISTURE FUSE T10AL 250V REPLACE ONLY WITH TANNOY PART 3461 0...

Page 11: ...80Hz 38kHz 120dB average 126dB peak 90 Degrees Conical 1 x 300mm 12 Dual Concentric 8 2 averaged 1kHz to 10kHz 8 8 averaged 1kHz to 10kHz 2nd Harmonic 3rd Harmonic 0 56 0 23 2 36 1 88 2 68 0 08 2nd H...

Page 12: ...protection recovery Inrush current limiting 1x Limit LED 1x Signal LED 1x Power LED one Class D Locking Neutrik Powercon Automatic 115 230V 45 65Hz High current high freq switch mode 90 typical 100V...

Page 13: ...using the accessory kits supplied and in strict compliance with the user manual The use of other accessories or non approved methods of assembly may result in an unsafe hardware system by reducing th...

Page 14: ...made depending on the application and the coverage pattern required see figures 1 2 Using the VCS ceiling saddle the resulting cluster can be attached to the ceiling VCB4 The VCB4 cluster bar availabl...

Page 15: ...DESCRIPTION Cluster Bar Washer M10 Plain Screw M10x40 Button Head M10 Nyloc Nut Blanking Plug QUANTITY 1 2 2 2 2 Contents of VCB2 1 2 3 4 5 DESCRIPTION Cluster Bar Washer M10 Plain Screw M10x40 Butto...

Page 16: ...er on Assembly View Fig 3 Description Quantity 1 Hanging Bracket 2 2 Cross Member 1 3 Pivot Stud 2 4 M10 Plain Washer 2 5 M8 Spring Washer 2 6 M10 Spring Washer 4 7 M10 x 30mm Screw 2 8 M8 x 20mm Scre...

Page 17: ...17 10 4 SECUR ET V15Y V12Y V15Y V12Y...

Page 18: ...fixing obtained There are also two holes either side of the fixing beam to allow the speaker cable the pass through the wall plate and along the fixing beam to the terminal panel resulting in a more d...

Page 19: ...e desired angle Important It is imperative for safety reasons that two eyebolts linked to two independently fixed straps are used per cabinet VEB eyebolts should be installed into the relative sides o...

Page 20: ...available in both black and white finishes and is to be used in conjunction with the VMY and a length of M10 threaded rod not supplied by Tannoy Limited The VCS ceiling saddle allows the Tannoy Power...

Page 21: ...ne Kit 2522 PowerV15BP 7900 0596 Driver Kit 3813 7900 0600 Recone Kit 3813 PowerV HARDWARE 8001 2780 VMY Secur ET Yoke Adjustable Black 8001 2790 VMY Secur ET Yoke Adjustable White 8001 2800 VMB Secur...

Page 22: ...s is are manufactured in UK by Tannoy Ltd of Rosehall Industrial Estate Coatbridge Scotland ML5 4TF The following equipment is marked with the CE label and conform s to the protection requirements of...

Page 23: ...14 0 NOTES...

Page 24: ...NOTES...

Page 25: ...NOTES...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...ct specification is subject to change Tannoy United Kingdom T 44 0 1236 420199 F 44 0 1236 428230 E enquiries tannoy com Tannoy North America T 519 745 1158 F 519 745 2364 E inquiries tannoyna com Tan...