![T&D RTR-5 US User Manual Download Page 66](http://html1.mh-extra.com/html/tandd/rtr-5-us/rtr-5-us_user-manual_3076494066.webp)
61
RVR-
52
A: Start Recording
Here all settings and communication for RVR-
52
A (Wireless Voltage /
Pulse Data Loggers) can be carried out. Connect a RVR-
52
A Data
Logger to your computer so that communication can occur and check
to make sure that your computer system clock is correct.
* For details about connecting the Data Logger, Please see P.
21
for details.
1
.
In the Main Window, click the icon [RVR-
52
A].
2
.
Click the [Start Recording] Tab and make recording settings.
[Close]
Button
[Start Recording]
Button
[Get Settings] Button
[Stop Recording]
Button
[Start Recording] Tab
[Detailed Settings]
Button
Recording Start Date and Time
Select the Recording Start Method
- Programmed Start : Recording will begin on the day and time entered.
- Immediate Start : Recording will begin as soon as settings are
completed.
Recording Interval
Select from:
1
,
2
,
5
,
10
,
15
,
20
,
30
seconds
1
,
2
,
5
,
10
,
15
,
20
,
30
,
60
minutes. By clicking [
▼
] you can select from the recording interval list.
Recording Mode
- One-time : When the number of readings has reached
16
,
000
, the unit
display will read [FULL] and recording will automatically stop.
- Endless : When the number of readings reaches
16
,
000
, the next one
will overwrite the oldest or first reading.