4 TC36.CSTE
082406-40
IMPORTANT NOTE FOR THE COMMONWEALTH OF MASSACHUSETTS
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a)
For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall
exhaust vent termination is less than seven (7) feet above fi nished grade in the area of the venting, including but not limited to
decks and porches, the following requirements shall be satisfi ed.
1.
INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented
gas fuelled equipment, the installing plumber or gasfi tter shall observe that a hard wired carbon monoxide detector with an
alarm and battery back-up is installed on the fl oor level where the gas equipment is to be installed, in addition, the installing
plumber or gasfi tter shall observe that a battery operated or hard-wired carbon monoxide detector with an alarm is installed on
each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fuelled equipment. It
shall be the responsibility of the property owner to secure the services of qualifi ed licensed professionals for the installation of
hard-wired carbon monoxide detectors.
a.
In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the
hard-wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent fl oor level.
b.
In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner
shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30)
day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2.
APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with
the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certifi ed.
3.
SIGNAGE. A metal or plastic identifi cation plate shall be permanently mounted to the exterior of the building at a
minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas
fuelled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT
DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4.
INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not
approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in
accordance with the provisions of 248 CMR 5.089(2)(a) 1 through 4.
(b)
EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1.
The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of
NFPA 54 as adopted by the Board; and
2.
Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the
dwelling, building or structure used in whole or in part for residential purposes.
(c)
MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufac-
turer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system
components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting
system shall include:
1.
Detailed instructions for the installation of the venting system design or the venting system components; and
2.
A complete parts list for the venting system design or venting system.
(d)
MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manu-
facturer of a Product Approved side wall horizontally vented gas fuelled equipment does not provide the parts for venting the
fuel gases, but identifi es “special venting systems”, the following requirements shall be satisfi ed by the manufacturer.
1.
The referenced “special venting system” instructions shall be included with the appliance or equipment installation
instructions; and
2.
The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
(e)
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all
venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance
or equipment at the completion of the installation.
Summary of Contents for TC36ST
Page 38: ...38 TC36 CSTE 082406 40 NOTES...
Page 39: ...082406 40 TC36 CSTE 39 NOTES...