082406-40
TC36.CSTE 25
GAS SUPPLY
Caution: The gas line should be installed by a qualifi ed
service person in accordance with all building codes. This
section is intended as a guide for qualifi ed technicians
installing this appliance. Consult local and/or national
building codes before proceeding.
A gas supply line access hole is located at the bottom right
side of the Control Box. Gas valve inlet accepts a 3/8" N.P.T.
fi tting. Correct gas line diameter must be used to assure
proper operation.
The gas control is equipped with a capture screw type pres-
sure test port, therefore it is not necessary to provide an 1/8
inch N.P.T. plugged tapping pressure port for checking gas
pressure immediately upstream of the gas supply connection
to the appliance.
FIREBOX PANELS INSTALLATION
Correct gas pressure requirement:
Natural
Gas Propane
Min. Pressure
5.0" wc
12.5" wc
(For purpose of input adjustment)
Max. Pressure
13.9" wc
13.9" wc
Manifold
Pressure
Maximum
3.8" wc
11.0" wc
Minimum
2.1" wc
5.5" wc