D 13373.08
NOVEMBER 2007
MPS
TANDBERG
MPS
ADMINISTRATOR GUIDE
G.703 Board
PRI Board Configuration
!
Please ensure that
Network Type
is set to
G.703
for
the correct ISDN cards in the
PRI Network Configura-
tion
.
Network Configuration
Physical Layer
Select
E1
(max 30+1 channels) or
T1
(max 23+1 channels) to
match your ISDN network.
G.703 Board
Leased Line is a non-dialling protocol. Should be used when:
One codec is connected in a point to point connection
1.
Through an ISDN switch supporting G.703 Leased Line
2.
mapping.
NOTE!
It may be necessary to specify the call rate explicitly
when dialling a G.703 call id to ensure that the correct call
rate is used.
G.703 Board Interfaces (1:2)
Save
- Press the Save button to save changes.
Interface (1 to 8)
The interface number refers to the port number/G.703 inter-
face of the Network Interface Card.
Enable
On:
If set to On, the port is enabled for G.703 use.
Off:
If set to Off, the port is disabled for G.703 use.
Slot (1 to n)
Select Slot
1
to
6
to configure the G.703 (Leased Line) board.
The picture shows one G.703 board installed in Slot 3.
Indicates ok
Indicates an error
95