About G.703 Ports
G.703 Ports:
To address the G.703 ports in a dialling rule
the physical G.703 ports have a numeric
representation with two digits for each the
interface number and the module number as
well as a one digit representation for the call
number.
Make sure that this string always contains 5
digits.
Range will therefore be 01011 to 06085 for
corresponding G.703 cards/modules in slot 1
port 1 call 1 to slot 6 port 8 call 5.
Example:
Slot 1 Port 1 Call 1: 01011
Slot 1 Port 1 Call 2: 01012
Slot 1 Port 1 Call 3: 01013
....
Slot 1 Port 8 Call 3: 01083
Slot 1 Port 8 Call 4: 01084
Slot 1 Port 8 Call 5: 01085
Slot 6 Port 1 Call 1: 06011
Slot 6 Port 1 Call 2: 06012
Slot 6 Port 1 Call 3: 06013
....
Slot 6 Port 8 Call 3: 06083
Slot 6 Port 8 Call 4: 06084
Slot 6 Port 8 Call 5: 06085
Example 1: DID
The J3 software and above supports
H.323 to G.703 Gateway.
Example with DID:
You would like to have a DID number from
H.323 to G.703.
Add Dialling Rule
Set
1.
Type
to
DID
Select
2.
Bandwidth
Set
3.
Number of Significant Digits
to empty
or to
0
(zero)
Set
4.
From Network Type
to
H.323
Set
5.
From Prefix
to
9
Set
6.
To Network Type
to
G.703
Leave
7.
To Prefix
empty
To call G.703 call 1 on port 1 on module card
1 would require you to dial 901011 from the
H.323 endpoint.
Example with DID:
You would like to have a DID number from
H.323 to a specific G.703 call.
Add Dialling Rule
Set
1.
Type
to
DID
Select
2.
Bandwidth
Set
3.
Number of Significant Digits
to empty
or to
0
(zero)
Set
4.
From Network Type
to
H.323
Set
5.
From Prefix
to
9
Set
6.
To Network Type
to
G.703
Set
7.
To Prefix
to
01062
To call G.703 call 2 on port 6 on module card
1 would require you to dial 9 from the H.323
endpoint.
Example with DID:
You would like to have a DID number from
H.323 to a specific G.703 card.
Add Dialling Rule
Set
1.
Type
to
DID
Select
2.
Bandwidth
Set
3.
Number of Significant Digits
to empty
or to
0
(zero)
Set
4.
From Network Type
to
H.323
Set
5.
From Prefix
to
9
Set
6.
To Network Type
to
G.703
Set
7.
To Prefix
to
01
To call G.703 call 3 on port 2 on module card
1 would require you to dial 9023 from the
H.323 endpoint.
Example 3: DID
Example 2: DID
Examples with G.703 Gateway
For further information about how the
video system endpoint supports TCS-4
please see the MXP Administrator’s
Guide on
.
117
Introduction
Quick
Setup
Using
the MPS
System
Status
System
Configuration
Installation
MCU
Configuration
Technical
Descriptions
Appendices
Main
Gateway
Configuration