CHAPTER 4: Thermal Specifications
To evaluate different modes of operation, data was recorded either with data
compression enabled or disabled. Thermocouples were affixed to key board
components as shown in
Figure 4-2
. In addition, a thermocouple was placed within
the tape path enclosure to monitor the approximate temperature of the media, as
shown in
Figure 4-4
.
The results of the testing are listed in
Table 4-1
and
Table 4-2
below.
Table 4-1.
SDLT 220/320 Steady State Temperatures: Embedded Bezel
Component
10 degrees C
Ambient
25 degrees C
Ambient
40 degrees C
Ambient
Case
Maximum *
Continuous
Operating
Temperature
(degrees C)
Compression
2:1
Compression
2:1
Compression
2:1
On
Off
On
Off
On
Off
Temperature
(degrees C)
Temperature
(degrees C)
Temperature
(degrees C)
1
HiFN
42.4
39.9
57.4
55.0
72.5
69.6
96
2
Hydra 1
45.8
46.5
61.3
62.0
77.4
76.9
113
3
Hydra 2
42.3
42.9
57.6
58.5
73.6
73.2
113
4
Coldfire
23.3
23.4
38.5
38.5
53.6
53.5
83
5
3.3-5.0 V Reg
34.2
33.4
49.4
48.8
64.7
63.8
119
6
Front Sensor
17.0
17.0
32.0
32.0
47.0
47.0
52
7
Rear Sensor
35.2
34.3
50.2
49.9
65.8
64.7
125
8
Headboard
33.2
33.9
47.7
48.4
62.8
62.7
125
9
Qlogic
29.7
29.3
45.3
45.0
60.9
60.1
80
10
Media Sensor
(Heads)
19.3
19.6
34.6
34.7
50.3
50.2
n/a
* The number in the Case Maximum Continuous Operating Temperature column are absolute limits that
should not be exceeded. In other words, expect physical component damage or failure if you exceed these
operating temperature limits by not providing adequate air flow through the drive.
Summary of Contents for SDLT220-320 INTEGRATION
Page 1: ...TANDBERG Super DLTTM Design Intergration Guide Revision 1 June 2002 432588 01...
Page 4: ...SDLT 220 and SDLT 320 Design Integration Guide...
Page 18: ...CHAPTER 1 Introduction...
Page 24: ...CHAPTER 2 General Drive Specifications Figure 2 6 Front Views of SDLT 220 320 Tape Drive...
Page 53: ...CHAPTER 4 Thermal Specifications Figure 4 3 HIM Board Thermal Measurement Location Qlogic...
Page 80: ...CHAPTER 6 SCSI and Controller Interface Specification...
Page 86: ...CHAPTER 7 Updating the Firmware...
Page 93: ......