background image

MasterControl

English

Page 7.5

7.3. Double tractions

Creating  double tractions

Move the locomotives behind each other and set the same driving direction for both of them.

Please note: A double traction is only possible,  if  both  decoders  have  the  same  amount  of speed
levels.  A  double  traction  with  decoders  of  different  formats  is  possible,  if  both  decoders  are
runni ng with 14 speed levels or the Motorola decoder is running at 27 and  the  DCC  decoder  at  28
speed levels. If you  try  to create  double  tractions  of  decoders  with  a  different  amount  of  speed
levels, your MasterControl displays an error message.

216    DCC    0 

BR216       

 

 

 

 

Enter the address of the first locomotive and confirm by pressing
 #   /  ok.
Hint:

It is easier switching the functions of the locomotive first set after
installing double traction.

Just press    #  / ok again.

#-ADR: 3      0

* = Cancel  

 

 

 

 

Then enter the address of the second locomotive and confirm by
pressing   #  /  ok.

To cancel an input, press     *  / esc.

216  

 DCC    0

3     

 

 

 

 

 

 

 

 

Both addresses will be displayed on top and on the bottom of the
display. Both locomotives now respond simultaneously to driving
commands or a direction change.

The lock sign (

) displays that the double traction cannot be taken

over by another control unit.

Switch ing the functions of  double tractions

216  

 DCC    0

3     

 

F

2

 

 

   

F

1

 

 

You can switch the functions f0  and function f1 to f4 of both
locomotives in the double traction separately. Switching functions
f5 to f8 is not possible.

You switch the functions of the locomotive displayed in the upper
row of the display (the first locomotive) by pressing  function ,  f1 ,
 f2  ,  f3  or    f4  . To switch the functions of the locomotive
displayed in the lower row of the first display (the first locomotive)
by additionally holdi ng the shift key.
The active functions of the first locomotive are displayed in the
right lower row and for the second locomotive in the middle lower
row. In our example locomotive number 216 has the active
functions f0 and f1, locomotive 3 the active function f2.

Summary of Contents for MasterControl 40-01007

Page 1: ...n Information and tips www tams online de Warranty and service Tams Elektronik GmbH Rupsteinstra e 10 D 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail modellbahn tams online de 10 2...

Page 2: ...n Information and tips www tams online de Warranty and service Tams Elektronik GmbH Rupsteinstra e 10 D 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail modellbahn tams online de 10 2...

Page 3: ...on and serial number 6 21 6 8 Exit 6 21 7 Operation 7 1 7 1 Switching track power on and off 7 1 7 2 Driving locomotive and function decoders 7 2 7 3 Double traction 7 5 7 4 Driving solenoid accessory...

Page 4: ...English MasterControl Page 0 2...

Page 5: ...s of the EasyControl and is the central input device for all parameters of the model railroad control The MasterControl also has it s own database to store all settings Section 5 Features of your Mast...

Page 6: ...ooster recognizes a short circuit too high power consumption it calls the MasterControl The MasterControl then switches off the booster and displays a warning 9 Breaking distance booster Through the o...

Page 7: ...for other 8 Driving booster 2 Power supply bus systems 9 Breaking distance 3 Non central control 6 BusControl booster devices 10 s88 Module 4 SwitchControl 7 DCC programming track 11 PC 5 6 4 3 7 1 3...

Page 8: ...English MasterControl Page 1 4...

Page 9: ...ench 4 for Dutch Saftey instructions EayControl should only be used in concordance with these instructions It is not suitable for use by children under 14 Incorrect use can be dangerous In particular...

Page 10: ...tep Explanations 1 Overview of the display and controls of the MasterControl Section 4 2 Connecting booster and power supply Section 3 3 Switching on AC power Section 7 1 4 Overview of the parameter s...

Page 11: ...circuit polarity can be set on the MasterControl As this setting applies to all connected boosters only one type of booster may be connected to your MasterControl Section 11 Background information Pi...

Page 12: ...Only DCC decoders can be programmed using the DCC programming track port Motorola decoders featuring online programming can be programmed on your layout or on an oval track which is connected to the...

Page 13: ...it an input can be confirmed or during operation mode the driving direction can be changed The MasterControl and LokControl look alike To distinguish between them the speed control knob has different...

Page 14: ...English MasterControl Page 4 2...

Page 15: ...ilCom 27 speed levels with the Motorola format The Motorola format standardly supports 14 speed levels Your MasterControl additionally offers two methods to extend those speed levels to 27 Speed level...

Page 16: ...This way the EasyControl makes it possible to operate locomotives with Motorola and DCC decoders at the same time Creating double tractions Assigning names to locomotives additionally to assigning add...

Page 17: ...ction 7 6 Resetting your system Saving and restoring your layout status The layout status can be saved at any time Every setting of any active locomotive and function decoders will be saved including...

Page 18: ...English MasterControl Page 5 4...

Page 19: ...on both methods Whenever you read press ok to confirm your input pressing the speed control knob is also possible Display Action Button Call the menu Press 0 menu Navigating forward on the same menu l...

Page 20: ...ayout status 3 2 Restore layout status 4 1 Mode 128 speed levels 4 2 Mode speed controller 4 3 s88 settings 4 1 1 S 88 module 4 1 2 S 88 module test 4 4 Delete the configuration 4 5 Booster configurat...

Page 21: ...polarity Baud rate of the serial interface 2400 Settings Interface baud rate Data format of points points format Motorola format Settings Points Format Min switching time for points 100 ms Settings P...

Page 22: ...Return to normal operation mode by pressing esc The submenu enables you to Search for a locomotive s name in the database and select it to operate Individually apply or change parameters for each dec...

Page 23: ...ve s address Name 99 EMMA or Name 99 ok Possible actions To change enter a name press ok Navigate to another menu point by turning the speed control knob Go back to the main menu level by pressing esc...

Page 24: ...r menu point of the submenu level 1 by turning the speed control knob Go back to the main menu level by pressing esc FS128 1 1 Possible actions Choose the mode for speed level mode 128 by turning the...

Page 25: ...value of the variable is not read from the decoder Please note Each DCC decoder is designed for special modes of programming To find out which mode your decoder supports please read the manual Section...

Page 26: ...avigate to another menu point of the submenu level 1 by turning the speed control knob Go back to the main menu by pressing esc Primary address 103 The MasterControl automatically reads the decoder s...

Page 27: ...ister value on t he right Possible actions Reading a register Enter register number on the keypad only possible if the cursor is centred on the register number field and confirm input with ok The save...

Page 28: ...bmenu level 1 by turning the speed control knob Go back to the main menu by pressing esc RailCom CV 29 Possible actions Reading out the CV of a vehicle decoder Enter the no of the CV on the keypad and...

Page 29: ...b Go back to the operation mode by pressing esc Save layout status ok Possible actions To save layout status press ok To restore layout status turn the speed control knob until Restore layout status i...

Page 30: ...actions To navigate to submenu level 2 press ok Navigate to another menu point in submenu level 1 by turning the speed control knob Go back to the main menu by pressing esc Mode for speed level mode 1...

Page 31: ...speed control knob further counterclockwise shows no effect In DC speed controller mode both turning the speed control knob clockwise and counterclockwise effect an increase of the speed level When t...

Page 32: ...ayed check results press 0 menu Differences between the displayed status and the current status of an s88 module point to errors concerning your s88 bus your s88 module or parts of your model railway...

Page 33: ...thout saving changes Hint The use M rklin compatible boosters requires setting the short circuit polarity to positive and for DDC compatible boosters to negative Short c sens 100 ms ok Possible action...

Page 34: ...00 and can t be changed Making settings for solenoid accessory decoders Points config ok Possible actions To set the points format press ok Navigate to another menu point in submenu level 1 by turning...

Page 35: ...up of four points and ok To set the points format for this group press ok Navigate to another menu point in submenu level 1 by turning the speed control knob Go back to the main menu by pressing esc P...

Page 36: ...anges Hints When setting a certain minimum switching time you can switch points by quickly tapping the function key although the points need a longer switching time max switch time 5 0 s ok Possible a...

Page 37: ...andard settings for Motorola is 14 speed levels and for DCC 28 speed levels Using the locomotive menu you can set a different data format and or another amount speed levels Setting duration of the sig...

Page 38: ...sible adjustments 0 off The Railcom support is switched off 1 Tailbits There will be left space for the RailCom cutout during data transfer 2 IdNotify The central unit sends regularly it s identificat...

Page 39: ...cklight 8 Possible actions Adjust the LCD backlight by turning the speed control knob Possible values 0 to 16 Confirm input by pressing ok You ll then be taken back to the main menu Cancel with esc Yo...

Page 40: ...English MasterControl Page 6 22...

Page 41: ...ave additional power buffers which can support a locomotive when power is cut Before operating such a decoder please check how much energy is stored and which of the locomotives is able to move withou...

Page 42: ...driving directions is sent and thus no such information is displayed Enter address ADR 216 0 Cancel ok Please enter the locomotive or function decoder s address using the keypad When entering the fir...

Page 43: ...ion the current speed level is set to 0 which causes some decoders to execute an emergency stop With the DC mode set for the speed controller the driving direction is set by the rotating direction of...

Page 44: ...n and off with the button function afterwards This method allows you to switch the functions f1 to f12 Displaying functions switched on When pressing shift for the last called locomotive whose data is...

Page 45: ...and confirm by pressing ok To cancel an input press esc 216 DCC 0 3 Both addresses will be displayed on top and on the bottom of the display Both locomotives now respond simultaneously to driving comm...

Page 46: ...itching decoder out put off Switching time The signal to switch points or a switching decoder is sent as long as you press the functions key Nonetheless the minimum and maximum switching time is limit...

Page 47: ...ok The locomotive is then locked and the lock sign is displayed Entering the address again or entering another turns the lock off Specialities of a double traction A double traction stays under contr...

Page 48: ...English MasterControl Page 7 8...

Page 49: ...pdate application Please note Always connect the MasterControl to your PC before executing the update application Otherwise your PC might have difficulties detecting the interface Follow the instructi...

Page 50: ...English MasterControl Page 8 2...

Page 51: ...epeat your input and if necessary enter additional blanks When switching on the MasterControl it blocks when displaying its version number Possible reason The locomotive database contains corrupted da...

Page 52: ...e causing problems They do not respond to driving or function commands or have an odd driving behaviour Possible reason The duration of the signal pause is set inaccurately Change the duration of the...

Page 53: ...ooster s88 feedback module RS232 PC USB PC EasyNet e g for LokControl Maximum amount of s88 modules 32 s88 or s88 compatible modules Maximum amount of locomotive addresses 255 in the Motorola format 1...

Page 54: ...36 EWG on electromagnetic radiation and is therefore CE certified Guarantee Conditions This product carries a two year garantee covering material defect and fabrication errors We also guarantee the ad...

Page 55: ...mation about the status of the four functions and the absolute driving direction The Motorola II format allows only 14 speed levels as well In the meantime decoders have become available which support...

Page 56: ...mming allows you to set a decoders properties by setting the so called configuration variables CV variables The meaning of each variable is clearly defined by the NMRA Each variable has 8 bits and can...

Page 57: ...s is facilitated by switching on off the power The interval between those power peeks is called PMW period By altering the PMW period the individual running characteristics of an electric motor are ch...

Page 58: ...r consumption a locomotive Gauge N 600 mA Gauge H0 800 mA Gauge 0 1 A a wagon light 50 200 mA another consumer such as a sound module 100 300 mA reserve for points 10 of the calculated sum of power co...