Shown
in the display
Colour of the RGB
LEDs
Meaning
LP
red
"Low Power". The input voltage after
switching on is below 22 V. Disconnect the
control unit from the supply voltage
immediately!
Troubleshooting → section 8.3
Fr
red
The configuration is deleted and the mc²
is reset to the factory settings.
1...99 or ---
violet
circulating
An update is being carried out. The digits
indicate the progress in %. During writing,
the progress display is interrupted.
[ ]
blue
flashing
+ white
swelling
The update is being processed and
completed.
E + digit
no colour change
An internal error has occurred. Please
make a note of the digit(s) and contact
the hotline.
Dots flash
alternately
violet
The recovery software has been started.
→ Section 7
Setting options for the RGB LEDs
On the "Home" page of the Toolbox, you can activate and deactivate the following functions of
the RGB LEDs:
Light effects ("boredom mode")
Dim light. If the function is activated, in standard mode the green and the red lighting (as
an indication of switched on or switched off track voltage) is reduced after the LEDs light up
briefly.
Operation with the mc² | 6.3