6.1.2. Display and RGB-LEDs
Shown
in the display
Colour of the
RGB LEDs
Meaning
0.0 to 6.5
green
current current consumption [A]
The track voltage is switched on.
St.
red
Stop. The track voltage is switched off.
td
green
"Test Drive". In test mode you can control
and test vehicle and accessory decoders
on the programming track with the virtual
control units HandControl.prog. and
FunctionControl.prog.
SH
red violet
flashing
"Short Circuit" / short circuit during
operation.
Troubleshooting → section 8.2
ot
yellow orange
red
flickering
"Overtemperature" / Overheating
Troubleshooting → Section 8.2
rE
blue
flashing
+ white
swelling
A reset is performed.
St.
blue
circulating
Stop / The track voltage is switched off.
If the STOP button was previously held longer, the
command for the BiDiB Identify for the mc² is sent.
PA
no colour change
Pairing. Control software is loaded for the
first time on a connected PC or mobile
terminal
IP|12|3.4|56.|78|9.1|23
no colour change
IP address
The individual digits of the IP address are retrieved by
pressing the "GO" key several times. → Section 2
Pf
red
"Power failure". The input voltage is below
22 V. Disconnect the control unit from the
supply voltage immediately!
Troubleshooting → section 8.3
6.2 | Operation with the mc²