TP-72S (Rev 1.2)
- 26 -
TALON TECH CO. LTD.
6-7
Notice on Pump Operation
1. During Pump is under process (RUN OR CYCLE)
don’t
try to modify the data.
(Please do it after Pump had stop properly)
▶
In this term of
“
modify data
”
means changing recipe, cycle, cal value etc. If you modified the data
during pump operation, BUSY screen will be pop-up and it will be not saved.
▶
Screen moving in touch pad is OK.
2. For Pump Recipe Setting, Recipe 1 and 4 are applied same.
▶
Dispense Volume => set the volume range between 100(1cc) ~ 2000(20cc)
▶
Reason : For protect the pump , upper limit alarm set.
▶
Dispense Time => It should be bigger than Dispense Volume. It should be smaller than system
recipe step time.
▶
Reason : As using the high cp PR , sudden pump operation could have the motor damaged and
could cause the MICRO BUBBLE.
▶
Reload Time => depend on PR cp.
▶
Typically, high cp PR case, adjust 3~8 times reload time than dispense volume.
ex) Dispense Reload
Vol[
300
] Time[500] Vol[300] Time[
900
]
▶
This would be main reason of bubble issues. So please watch out for this.
900
~ 2400