![Talon TP-72S Manual Download Page 12](http://html1.mh-extra.com/html/talon/tp-72s/tp-72s_manual_3423776012.webp)
TP-72S (Rev 1.2)
- 8 -
TALON TECH CO. LTD.
4-1 Track Interface Signal
Recipe Select Trigger
“
0
”
Trigger Off
“
1
”
Trigger On
Recipe
Select
Start1
[1]
Start2
[2]
Start3
[3]
Remark
1
1
0
0
2
0
1
0
3
1
1
0
4
0
0
1
Cycle Recipe
5
1
0
1
6
0
1
1
7
1
1
1
It is Timing Chart. On Ready condition, when Start Signal becomes active, each signal is same as the
chart. When Stop Alarm occurs, all stop even during dispensing. But, the warning alarm does dispense.
The alarm becomes clear by reset after pump clear.
Track / Auxiliary Interface
4