![Talon TP-72S Manual Download Page 15](http://html1.mh-extra.com/html/talon/tp-72s/tp-72s_manual_3423776015.webp)
TP-72S (Rev 1.2)
- 11 -
TALON TECH CO. LTD.
4-3-2 Track Cable
Pin
Number
Pump Cable(D-SUB 15P)
Controller
Pump
1
+5V
1 : 1
2
PUMP_CW
1 : 1
3
PUMP_CCW
1 : 1
4
+24V
1 : 1
5
E_HOME_SIGNAL
1 : 1
6
E_END_SIGNAL
1 : 1
7
E_MOTOR_ALARM
1 : 1
8
E_MOTOR_INPOSITION
1 : 1
9
GND
1 : 1
10
GND
1 : 1
11
Not Use
1 : 1
12
EX_IN_SOL V/V +24V
Sol V/V Connector share
13
E_SUCK_BACK_SOL_V/V +24V
1 : 1
14
EX_IN_SOL V/V -24V
Sol V/V Connector share
15
E_SUCK_BACK_SOL_V/V -24V
1 : 1
Pin
Number
Track Cable(D-SUB 15P)
N2 Type
Connecting Way
Controller
Track (ACT-12)
Track (ACT-12)
1
N.C
Not Use
Alarm is only for Stop. After
disconnecting EXT High 5,
link NO/COM with EXT 2P
cable.
Dispense Trigger links Suck-
Back V/V Cable from the
system after checking (+, -).
2
COM
EXT High 5 (link after disconnect)
3
N.O
EXT High 5 (link after disconnect
)
4
START 3
Not Use
5
START 1
Dispense Trigger ( - ) 2P
6
START 2
Not Use
7
IN SOL
Not Use
8
ALARM STOP
Not Use
9
ALARM WARNING
Not Use
10
HOME
Not Use
11
END
Not Use
12
OUT SOL
Not Use
13
+24V
Not Use
14
+24V
Dispense Trigger (+24) 2P
15
MC GND
Not Use