VOIP-600
Series Phone
Configuration / Operation Manual
Page
46
of
94
Rev. 9/17/2014
Copyright 2014 Talk-A-Phone Co.
• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.
All prices and specifications are subject to change without notice. Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talk-A-Phone Co. All rights reserved.
3. Select the devices for which
Diagnostics Results is to be reported
i.
Button/Switch Integrity
: Select a report to be sent either on
Failure
of the Button or the Switch
or send
Always
. Select Activate an Auxiliary Output, Report via Call and/or Report via E-mail as
a notification mode for the report.
ii.
Speaker & Microphone
: Select a report to be sent either on
Failure
of the Speaker or the
Microphone or send
Always
. Select Activate an Auxiliary Output, Report via Call and/or Report
via E-mail as a notification mode for the report.
iii.
WEBS®
: Select a report to be sent either on
Failure
of the WEBS® or send
Always
. Select
Activate an Auxiliary Output, Report via Call and/or Report via E-mail as a notification mode for
the report.
4. Configure the
Speaker/Microphone/Line-level gain
. Default Speaker gain value is ‘2’, Line Level
Output gain value is ‘2’ and Microphone gain value is ‘12’ which provide accurate results for the Self
Diagnostics.
5.
Enter a number to call
and/or
Enter an E-mail ID
to send a report with the results of the Self
Diagnostics.
6. Select the event to
De-activate the Auxiliary Output
. De-activate the Auxiliary Output upon next
scheduled Self-Diagnostic OR De-activate the Auxiliary Output after the programmed custom duration
seconds.
7. Click
Apply
to save settings.