background image

 

Area of Refuge Command Unit 

Installation Instructions 

Model AOR-24/AOR-32 

Page 

5

 of 

13

 

 

Rev. 10/15/2015 

 

 

Copyright 2014 Talk-A-Phone Co.

 

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.  

All prices and specifications are subject to change without notice. 

Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talk-A-Phone Co. All rights reserved.

 

18.

 

Local Mode  

 

In  Local  Mode,  pressing  the  button  on any  of  the Talkaphone  Area  of  Refuge 
Emergency phones will cause the built in touch-tone telephone to ring. 

 
19.

 

Remote Mode 
In Remote Mode, pressing the button on any of the Talkaphone Area of Refuge 
Emergency phones will cause them to access a phone line to dial out. For this 
configuration,  connect  an  outside  phone(s) 

line  to  the  “IN”  position(s)  on  the 

punch down block. 

 

NOTE:

  See  Technical  Requirements,  page  2,  for  outside  phone  line 

requirements. 
 

 

20.

 

Day/Night Mode 

 

Day/Night Mode is primarily used when a facility has a guard on-site during the 
day  but  not  at  night.  It  may  also  be  used  in  any  situation  where  the  guard 
station is not always manned. When a Talkaphone Area of Refuge Emergency 
Phone  calls  and  the 

AOR-24/AOR-32 

is  in  Day/Night  mode,  it  will  ring  the 

Command  Unit’s  built  in  local  handset  phone  first,  ring  it  a  second  time  if  no 
one answers the first time, then if no one answers the second time it will dial a 
remote number. If no one should answer the remote number, it will re-ring the 
local phone and continue this cycle until either the phone is answered or times 
out  (see  Emergency  Phone  manual  for  information  on  setting  the  time-out.) 
When a guard leaves for the night, she can enter the code *36* to configure the 
consolidator  to  ring  the  remote  phone  first  and  then  switch  to  the  local  phone 
(see Software Programming, page 6). For Day/Night Mode connect an outside 
phone  line(s)  to  the 

“IN”  position(s)  on  the  punch  down  block.  This 

programming  must  be  done  for  each  of  the  consolidators  (3  consolidators  for 
the AOR-24) 

 

NOTE:

  See  Technical  Requirements,  page  2,  for  outside  phone  line 

requirements. 
 

 
 

21.

 

Sharing a Phone Line 
Another telephone instrument  (e.g. fax,  modem,  standard telephone,  etc.) can 
share  the  outside  phone  line(s)  with  the 

AOR-24/AOR-32 

by  connecting  the 

outside  phone  line(s)  to  the  “IN”  position(s)  on  the  punch  down  block  and 
connecting  the  telephone  instr

ument sharing the line to the “OUT” position(s). 

Be sure to set each consolidator in the 

AOR-24/AOR-32 

not to answer before 

Summary of Contents for AOR-8

Page 1: ......

Page 2: ...through the installation of this product and provide comprehensive operating instructions Please read this instruction manual completely and thoroughly before installing this product II Contents Befor...

Page 3: ...s must provide 1 At least 24 Volts at 20 mA off hook no current is drawn on hook 2 Either a disconnect pulse voltage drop at end of call or 30 seconds or silence after hang up no re order or howler f...

Page 4: ...fore mounting the enclosure NOTE Whenever possible it is best to keep the maximum clearance possible between analog phone lines and alternating current Running phone lines too close to hot VAC lines w...

Page 5: ...2 banks of eight 8 The emergency analog phones on the system can connect to either the incoming POTS PSTN line or the local phone built into the AOR 16 unit 13 Attach the incoming Emergency Phone line...

Page 6: ...ing must be done for each of the consolidators one 1 consolidator for the AOR 8 or two 2 consolidators for the AOR 16 NOTE See Technical Requirements p 2 for outside phone line requirements 17 Sharing...

Page 7: ...to ensure compliance with all national regional and local regulations Programming Instructions To program the AOR 8 or AOR 16 Command unit each bank of eight 8 Talkaphone Area of Rescue emergency ana...

Page 8: ...olidator to be programmed listen for 3 beeps 2 Enter Guard Access Code 31 3 Program the consolidator for Day Night Mode 63 4 Program the consolidator to call either Local first then Remote 35 Remote f...

Page 9: ...try to change Guard Access Code or Master Access Code Default Code is 30 12345678 30 14725836 Resets Consolidator programming to factory defaults 32 up to 8 digits Programs and stores a new Master Acc...

Page 10: ...a call is already being answered any other calls which come in will cause the appropriate LED to blink to indicate they are awaiting an open line As soon as the initial call has been completed any cal...

Page 11: ...ground only at the consolidator end The resistance on the line is not to exceed 25 ohms The following chart shows distances and recommended wire gauges Distance from AOR 8 16 to Emergency Information...

Page 12: ...p battery 6 My consolidator is not at my desk where the calls come in Is there a way to make the LED s remote so I can see who is calling Although the LED s cannot be made remote Emergency Information...

Page 13: ...line into the Local port If so contact Talk A Phone technical support I hear noise on the line 1 You are not using twisted shielded wire Fluorescent lights elevator machinery and many other devices ca...

Page 14: ...u through the installation of this product and provide comprehensive operating instructions Please read this instruction manual completely and thoroughly before installing this product II Contents Bef...

Page 15: ...olts at 20 mA off hook no current is drawn on hook 2 Either a disconnect pulse voltage drop at end of call or 30 seconds or silence after hang up no re order or howler feature If connected to a POTS l...

Page 16: ...lug phone and power connections back into phone in the correct order 6 Remove the three 3 Phillips screws from the left side of the unit which secure the hinged front cover shut 7 Carefully open the h...

Page 17: ...ly on a wall in an appropriate location per the instructions packaged with the strobe siren assembly 14 Three 3 outgoing low voltage power lines from the strobe siren assembly must be wired to the Bla...

Page 18: ...hone Area of Refuge Emergency Phone calls and the AOR 24 AOR 32 is in Day Night mode it will ring the Command Unit s built in local handset phone first ring it a second time if no one answers the firs...

Page 19: ...matter However once either the batteries are connected OR the 115 230 VAC 50 60Hz line is energized THE UNIT WILL BECOME HOT ENERGIZED 23 Connect the backup batteries The batteries and their correspon...

Page 20: ...dator will respond with three beeps Each consolidator will respond to all programming requests in one of two ways 1 Beep Command completed successfully 2 Beeps Error s detected If you hear two beeps e...

Page 21: ...ce each Consolidator has been programmed each Talkaphone Area of Refuge Emergency Phone must be programmed individually A call can be routed to the desired phone port by entering the following code 4X...

Page 22: ...tions are subject to change without notice Talk A Phone Scream Alert WEBS and WEBS Contact are registered trademarks of Talk A Phone Co All rights reserved 37 Local Mode 63 Day Night Mode 35 In Day Ni...

Page 23: ...ll is already being answered any other calls which come in will cause the appropriate LED to blink to indicate they are awaiting an open line As soon as the initial call has been completed any calls t...

Page 24: ...h ground only at the consolidator end The resistance on the line is not to exceed 25 ohms The following chart shows distances and recommended wire gauges Distance from EC 8 to Emergency Information Te...

Page 25: ...battery 6 My consolidator is not at my desk where the calls come in Is there a way to make the LED s remote so I can see who is calling Although the LED s cannot be made remote Emergency Information p...

Page 26: ...line into the Local port If so contact Talk A Phone technical support I hear noise on the line 1 You are not using twisted shielded wire Fluorescent lights elevator machinery and many other devices ca...

Page 27: ...u through the installation of this product and provide comprehensive operating instructions Please read this instruction manual completely and thoroughly before installing this product II Contents Bef...

Page 28: ...olts at 20 mA off hook no current is drawn on hook 2 Either a disconnect pulse voltage drop at end of call or 30 seconds or silence after hang up no re order or howler feature If connected to a POTS l...

Page 29: ...lug phone and power connections back into phone in the correct order 6 Remove the three 3 Phillips screws from the left side of the unit which secure the hinged front cover shut 7 Carefully open the h...

Page 30: ...ly on a wall in an appropriate location per the instructions packaged with the strobe siren assembly 14 Three 3 outgoing low voltage power lines from the strobe siren assembly must be wired to the Bla...

Page 31: ...hone Area of Refuge Emergency Phone calls and the AOR 24 AOR 32 is in Day Night mode it will ring the Command Unit s built in local handset phone first ring it a second time if no one answers the firs...

Page 32: ...matter However once either the batteries are connected OR the 115 230 VAC 50 60Hz line is energized THE UNIT WILL BECOME HOT ENERGIZED 23 Connect the backup batteries The batteries and their correspon...

Page 33: ...dator will respond with three beeps Each consolidator will respond to all programming requests in one of two ways 1 Beep Command completed successfully 2 Beeps Error s detected If you hear two beeps e...

Page 34: ...ce each Consolidator has been programmed each Talkaphone Area of Refuge Emergency Phone must be programmed individually A call can be routed to the desired phone port by entering the following code 4X...

Page 35: ...tions are subject to change without notice Talk A Phone Scream Alert WEBS and WEBS Contact are registered trademarks of Talk A Phone Co All rights reserved 37 Local Mode 63 Day Night Mode 35 In Day Ni...

Page 36: ...ll is already being answered any other calls which come in will cause the appropriate LED to blink to indicate they are awaiting an open line As soon as the initial call has been completed any calls t...

Page 37: ...h ground only at the consolidator end The resistance on the line is not to exceed 25 ohms The following chart shows distances and recommended wire gauges Distance from EC 8 to Emergency Information Te...

Page 38: ...battery 6 My consolidator is not at my desk where the calls come in Is there a way to make the LED s remote so I can see who is calling Although the LED s cannot be made remote Emergency Information p...

Page 39: ...line into the Local port If so contact Talk A Phone technical support I hear noise on the line 1 You are not using twisted shielded wire Fluorescent lights elevator machinery and many other devices ca...