disconnect  the  incoming  power  cord  and  telephone  wires.  Take  care  to  keep 
these wires in the correct order.   

 
11.

 

For Flush Mounting the Unit 

 

The 

AOR-24/AOR-32

 has four(4) 7/32 [in] knockouts located on the top, bottom 

and  sides  which  can  be  used  for  either  mounting  the  unit  within  a  wall.  or  to 
fasten the available  AOR-TR32 Flush Mount  Trim Ring. This trim ring may be 
installed  in  contact  with  the  closed  cover  without  inhibiting  the  functionality  of 
the hinge. 

 
12.

 

Secure  the 

AOR-TR32

  to  the 

AOR-24/AOR-32

  unit  in  the  desired  location 

using the provided 10-24 screws. This trim ring may be installed in contact with 
the closed cover without inhibiting the functionality of the hinge. 

 
13.

 

Installation of Strobe/Siren 
Mount the strobe/siren assembly on a wall in an appropriate location per the 
instructions packaged with the strobe/siren assembly.  

 
14.

 

Three (3) outgoing low voltage power lines from the strobe/siren assembly must 
be  wired  to  the  Black,  Red/white,  and  Orange  lead  wires  from  the  relays 
located  at  the  top  interior  of  the 

AOR-24/AOR-32

.  Same  color  wires  from  the 

strobe/siren and the 

AOR-24/AOR-32

should be connected together. 

 
15.

 

Installing Phone lines 
Bring in analog phone lines through conduit knockouts located on the rear, top, 
or  bottom  sides  of  the  unit.  Always  try  to  separate  power  lines  from 
communication  lines  as  much  as  possible  to  reduce  undesired  effects  on  the 
phone line. 

 
16.

 

The 

AOR-24/AOR-32 

supports  up  to  twenty-four  (24)  or  thirty-two  (32) 

emergency analog phones divided into three (3)  or four (4) banks of eight (8). 
Each  bank  consolidates  up  to  eight  (8)  Area  of  Refuge  Emergency  Analog 
Phones  lines  and  can  connect  to either  its own  incoming  POTS  line  or phone 
built into the 

AOR-24/AOR-32 

unit. 

 
17.

 

Attach the incoming Emergency Phone lines to the correct pins on the 66-block 
as  indicated  on  the  diagram  found  beside  the  punch-down  block.  The 
connections are NOT polarity sensitive. If a telephone (POTS) line or PBX line 
is to be used in addition to the phone built into the enclosure, punch down the 
incoming phone line to the Telco 

“IN” positions of the same bank on the punch 

down block.  

 

 

Summary of Contents for AOR-8

Page 1: ......

Page 2: ...through the installation of this product and provide comprehensive operating instructions Please read this instruction manual completely and thoroughly before installing this product II Contents Befor...

Page 3: ...s must provide 1 At least 24 Volts at 20 mA off hook no current is drawn on hook 2 Either a disconnect pulse voltage drop at end of call or 30 seconds or silence after hang up no re order or howler f...

Page 4: ...fore mounting the enclosure NOTE Whenever possible it is best to keep the maximum clearance possible between analog phone lines and alternating current Running phone lines too close to hot VAC lines w...

Page 5: ...2 banks of eight 8 The emergency analog phones on the system can connect to either the incoming POTS PSTN line or the local phone built into the AOR 16 unit 13 Attach the incoming Emergency Phone line...

Page 6: ...ing must be done for each of the consolidators one 1 consolidator for the AOR 8 or two 2 consolidators for the AOR 16 NOTE See Technical Requirements p 2 for outside phone line requirements 17 Sharing...

Page 7: ...to ensure compliance with all national regional and local regulations Programming Instructions To program the AOR 8 or AOR 16 Command unit each bank of eight 8 Talkaphone Area of Rescue emergency ana...

Page 8: ...olidator to be programmed listen for 3 beeps 2 Enter Guard Access Code 31 3 Program the consolidator for Day Night Mode 63 4 Program the consolidator to call either Local first then Remote 35 Remote f...

Page 9: ...try to change Guard Access Code or Master Access Code Default Code is 30 12345678 30 14725836 Resets Consolidator programming to factory defaults 32 up to 8 digits Programs and stores a new Master Acc...

Page 10: ...a call is already being answered any other calls which come in will cause the appropriate LED to blink to indicate they are awaiting an open line As soon as the initial call has been completed any cal...

Page 11: ...ground only at the consolidator end The resistance on the line is not to exceed 25 ohms The following chart shows distances and recommended wire gauges Distance from AOR 8 16 to Emergency Information...

Page 12: ...p battery 6 My consolidator is not at my desk where the calls come in Is there a way to make the LED s remote so I can see who is calling Although the LED s cannot be made remote Emergency Information...

Page 13: ...line into the Local port If so contact Talk A Phone technical support I hear noise on the line 1 You are not using twisted shielded wire Fluorescent lights elevator machinery and many other devices ca...

Page 14: ...u through the installation of this product and provide comprehensive operating instructions Please read this instruction manual completely and thoroughly before installing this product II Contents Bef...

Page 15: ...olts at 20 mA off hook no current is drawn on hook 2 Either a disconnect pulse voltage drop at end of call or 30 seconds or silence after hang up no re order or howler feature If connected to a POTS l...

Page 16: ...lug phone and power connections back into phone in the correct order 6 Remove the three 3 Phillips screws from the left side of the unit which secure the hinged front cover shut 7 Carefully open the h...

Page 17: ...ly on a wall in an appropriate location per the instructions packaged with the strobe siren assembly 14 Three 3 outgoing low voltage power lines from the strobe siren assembly must be wired to the Bla...

Page 18: ...hone Area of Refuge Emergency Phone calls and the AOR 24 AOR 32 is in Day Night mode it will ring the Command Unit s built in local handset phone first ring it a second time if no one answers the firs...

Page 19: ...matter However once either the batteries are connected OR the 115 230 VAC 50 60Hz line is energized THE UNIT WILL BECOME HOT ENERGIZED 23 Connect the backup batteries The batteries and their correspon...

Page 20: ...dator will respond with three beeps Each consolidator will respond to all programming requests in one of two ways 1 Beep Command completed successfully 2 Beeps Error s detected If you hear two beeps e...

Page 21: ...ce each Consolidator has been programmed each Talkaphone Area of Refuge Emergency Phone must be programmed individually A call can be routed to the desired phone port by entering the following code 4X...

Page 22: ...tions are subject to change without notice Talk A Phone Scream Alert WEBS and WEBS Contact are registered trademarks of Talk A Phone Co All rights reserved 37 Local Mode 63 Day Night Mode 35 In Day Ni...

Page 23: ...ll is already being answered any other calls which come in will cause the appropriate LED to blink to indicate they are awaiting an open line As soon as the initial call has been completed any calls t...

Page 24: ...h ground only at the consolidator end The resistance on the line is not to exceed 25 ohms The following chart shows distances and recommended wire gauges Distance from EC 8 to Emergency Information Te...

Page 25: ...battery 6 My consolidator is not at my desk where the calls come in Is there a way to make the LED s remote so I can see who is calling Although the LED s cannot be made remote Emergency Information p...

Page 26: ...line into the Local port If so contact Talk A Phone technical support I hear noise on the line 1 You are not using twisted shielded wire Fluorescent lights elevator machinery and many other devices ca...

Page 27: ...u through the installation of this product and provide comprehensive operating instructions Please read this instruction manual completely and thoroughly before installing this product II Contents Bef...

Page 28: ...olts at 20 mA off hook no current is drawn on hook 2 Either a disconnect pulse voltage drop at end of call or 30 seconds or silence after hang up no re order or howler feature If connected to a POTS l...

Page 29: ...lug phone and power connections back into phone in the correct order 6 Remove the three 3 Phillips screws from the left side of the unit which secure the hinged front cover shut 7 Carefully open the h...

Page 30: ...ly on a wall in an appropriate location per the instructions packaged with the strobe siren assembly 14 Three 3 outgoing low voltage power lines from the strobe siren assembly must be wired to the Bla...

Page 31: ...hone Area of Refuge Emergency Phone calls and the AOR 24 AOR 32 is in Day Night mode it will ring the Command Unit s built in local handset phone first ring it a second time if no one answers the firs...

Page 32: ...matter However once either the batteries are connected OR the 115 230 VAC 50 60Hz line is energized THE UNIT WILL BECOME HOT ENERGIZED 23 Connect the backup batteries The batteries and their correspon...

Page 33: ...dator will respond with three beeps Each consolidator will respond to all programming requests in one of two ways 1 Beep Command completed successfully 2 Beeps Error s detected If you hear two beeps e...

Page 34: ...ce each Consolidator has been programmed each Talkaphone Area of Refuge Emergency Phone must be programmed individually A call can be routed to the desired phone port by entering the following code 4X...

Page 35: ...tions are subject to change without notice Talk A Phone Scream Alert WEBS and WEBS Contact are registered trademarks of Talk A Phone Co All rights reserved 37 Local Mode 63 Day Night Mode 35 In Day Ni...

Page 36: ...ll is already being answered any other calls which come in will cause the appropriate LED to blink to indicate they are awaiting an open line As soon as the initial call has been completed any calls t...

Page 37: ...h ground only at the consolidator end The resistance on the line is not to exceed 25 ohms The following chart shows distances and recommended wire gauges Distance from EC 8 to Emergency Information Te...

Page 38: ...battery 6 My consolidator is not at my desk where the calls come in Is there a way to make the LED s remote so I can see who is calling Although the LED s cannot be made remote Emergency Information p...

Page 39: ...line into the Local port If so contact Talk A Phone technical support I hear noise on the line 1 You are not using twisted shielded wire Fluorescent lights elevator machinery and many other devices ca...

Reviews: