m~ÖÉ=QS=
açÅ=kç=UMPMTRVLRJb==
=
OMMUJNNJNT=
Item
Name
Read /
Write
Description
Example
501
Reject reason counter
RW
Reads out information regarding the
reject reasons with coding as below.
1- Not seen in feed
3 - Close First, 4 - Close After
5 - Long A, 6 - Long B
7 - Thick A, 8 - Thick B
9 - Short A, 10 - Short B
11 - Thin A, 12 - Thin B
13 - Skew A, 14 - Skew B
To clear the reject counters, write ‘0’ to it.
Thick A
RD/501/7
Short B
RD/501/10
WD/501/0
502
Error status counter
RW
Reads out information regarding the
number of error status with coding as
below.
1 – Feed failure
4 – Mistracked note at exit
5 – Too long at exit
6 – Blocked exit
10 – Transport error
12 – Double detect error
13 - Diverter error
14 - Wrong count
15 - Note missing at double detect
16 - Reject rate exceeded
20 - Non volatile ram error
22 - Operation timeout
23 - Internal queue error
To clear the error counters, write ‘0’ to it.
Transport error
RD/502/10
Feed failure
RD/502/1
WD/502/0
503
Machine status
R
The internal machine status can be read
out with this item.
The LEDs on the MMC flashes also these
numbers if any status but NO_ERROR
occurs. Se chapter 2.5.
10 – OPERATION_TIMEOUT
19 - FEED_SENS_ERROR
20 - FEED_ERROR
21 - TOO_MANY_REJECTS
30 - NOTE_STUCK_IN_FEED
31 - NOTE_STUCK_IN_DDA
32 - NOTE_STUCK_IN_DDB
33 - NOTE_STUCK_IN_TRT
42 - TRANSP_START_ERROR
43 - TRANSP_RUNNING_ERROR
55 - NOT_REACHED_DD
57 - NOT_REACHED_TRT
62 - UNEXPECTED_TRT_NOTE
70 - FEED_QUEUE_OVERFLOW
71 - DD_QUEUE_OVERFLOW
72 - DIV_QUEUE_OVERFLOW
73 - TRT_QUEUE_OVERFLOW
74 - REJ_QUEUE_OVERFLOW
90 - TOO_MANY_NOTES_DELIVERED
92 - TROAT_BLOCKED
93 - UNABLE_TO_CALIBR_THROAT
97 - UNABLE_TO_CALIBR_DDA
98 - UNABLE_TO_CALIBR_DDB
99 - NVRAM_ERROR
Machine status
RD/503
Summary of Contents for MiniMech 010
Page 1: ...Doc No 8030763 05 EN Date 2010 02 05 MiniMech Documentation kit ...
Page 8: ...4 ...
Page 14: ...10 Note and Reject Cassette NRC 010 site preparation note reject cassette dimensions ...
Page 23: ...19 ...
Page 25: ...Doc No 8030758 02 EN 2009 06 04 MiniMech Users Manual D016720 ...
Page 26: ...This page is intentionally left blank ...
Page 39: ...Doc No 8030760 02 EN Date 2009 07 08 MiniMech 010 Service Manual ...
Page 40: ...This page is intentionally left blank ...
Page 47: ...Doc No 8030760 02 EN 9 Pulse disc sensor Exit sensor Overview Upper transport Lower transport ...
Page 79: ...Doc No 8030766 05 EN Date 2009 10 20 MiniMech 010 Parts List ...
Page 80: ...This page is intentionally left blank ...
Page 85: ...Doc No 8030766 05 EN 7 Parts List MiniMech 010 24 39 D016725_02 39 24 25 39 ...
Page 87: ...Doc No 8030766 05 EN 9 Parts List Separation mechanism 46 46 46 28 D016554_02 28 46 46 29 ...
Page 89: ...Doc No 8030766 05 EN 11 Parts List Note guide upper assy ...
Page 91: ...Doc No 8030766 05 EN 13 Parts List Note guide lower assy ...
Page 93: ...Doc No 8030766 05 EN 15 Parts List Inner guide ...
Page 95: ...Doc No 8030766 05 EN 17 Parts List CRR protector assy ...
Page 99: ...Doc No 8030766 05 EN 21 18 D016543_03 Parts List Cables ...
Page 101: ...Doc No 8030761 04 EN Date 2009 10 20 MiniMech 010 Level 2 NRC 010 Parts List ...
Page 102: ...This page is intentionally left blank ...
Page 104: ...Doc No 8030761 04 EN 4 Contents Preface 3 Obligations of the user 5 Parts List NRC 010 6 ...