MAINTENANCE
Every 100 Hours
Cleaning the Water Separator
WARNING
¡
¡
¡
¡
¡
Do not smoke or permit open flames
while handling fuel or working on the
fuel system.
¡
¡
¡
¡
¡
Stop the engine in a well-ventilated
place and allow it to cool down before
performing maintenance.
¡
¡
¡
¡
¡
Clean up spilled fuel immediately.
S
: Closed
1. Open the front cover.
2. Close the lever (2).
3. Loosen the ring (3), then remove the case
(4), element (5) and indicator ring (6) and
clean them.
4. Inspect the O-ring, and if there are any
scratches or other irregularities, replace
it.
5. Assemble the indicator ring (6), case (4)
and element (5) and tighten the ring (3).
6. Open the lever (2) and bleed the air.
Refer to page 139 “Bleeding the Air from
the Fuel System”.
K3G002
ON
OFF
6
3
S
5
4
2
1
7
8
Summary of Contents for TB125