General information
All whirltubs produced by are delivered on a self-supporting frame
with adjusted height. The system components (whirl pump, control
unit and blower) are located in places shown in the annexed
dimensioned diagram. In case of models where you can choose
between the factory-made right-hand and left-hand version, the
right-hand version is delivered as a standard (always looking from
the outside, standing in front of the drain/ over
fl
ow
fi
tting).
What you should pay attention to:
■
Check whether the delivery is complete and undamaged.
■
We will not be liable for damages that occur during
transport and storage.
■
Do not
raise the bathtub with previously installed pipe
system! Avoid any impacts!
■
During the installation cover the bathtub surface and any
system elements that stick out, which will protect them
against damages and excessive dirt.
■
Individual elements of the system must remain
accessible for later maintenance works!
People with various diseases such as serious infections, blood
clots, kidney failure, heart disease, diabetes should use the whirl
system after consultation with a doctor, which allows for the use of
appropriate therapy.
We also recommend medical consultation for pregnant women.
The whirl massage is exhaustive for children, they should not be
left unattended in such a bath.
The existing system is not intended for use by persons (also
children) with reduced physical, sensory or mental capabilities,
or people which do not have any experience or are not familiar
with the equipment unless it is done under adult supervision or in
accordance with usage instruction guidelines.
One must pay attention to children who should not have any
access to the device.
Older people that move slowly or disabled persons should use the
bath carefully.
02 Mounting/Installation
Place the bathtub and level it with the
help of plastic legs with adjusted height.
Protect the leg with a
fl
at securing nut.
For acoustic insulation (in order to avoid
the transfer of material sound to the wall),
use a wall pro
fi
le available in the market
(essential equipment). In case of models
that are intended to bo connected with
the wall, an edge strap for the bathtub is
essential (essential equipment: bathtub
anchor, install according to the attached
installation manual). During the installation please pay attention to
the fact that the apron must support the bathtub edge!
02.01 „Combi-Plus“
(additional equipment)
(bathtub tap with special drain / over
fl
ow
fi
tting)
An additional pipe interrupter is essential for the installation. Water
connection should be made according to the attached installation
manual.
02.02 Water supply installation
The water and drain system should be made in compliance with
the binding regulations.
At installation to potable water supply, service technician or user
must connect
fi
rst a safety device according to local regulations.
02.03 Electrical installation
The whirl tubs are designed for home usage (including hotels,
workers’ hostels, student hostels, etc.) and meet the requirements
included in relevant DIN/EN norms. An exception is using them for
medical purposes.
⚠
Notice:
All electrical works should be done by the
authorized electrician in accordance with the
applicable standard DIN/EN, typical country norms
and the local energy law!
The whirl system is designed to operate with the alternating
voltage of 230 V~AC, 50/60 Hz, 2kW. The electrical power of the
whirl system should be carried from a separate electric circuit and
properly protected with a 10 A fuze, in compliance with the rated
power consumption, according to the rating plate. Other users
cannot be connected. According to standards whirlpool baths as
I Class electrical devices must be permanently connected to the
electrical system via a bipolar disconnector. For security reasons,
the bath supply cable must be connected to the electricity only
through electrical connector secured by overcurrent disconnector
and differential current circuit breaker (RCD device) with a
nominal current of 30 mA, which will separate in all poles the
installation from electrical network leaving contacts open width of
at least 3 mm. The RCD device shall be veri
fi
ed at least once a
month. It is recommended that in situations when whirl tub is not
used for a longer time the whirl installation should be switched off
from the power supply system with the use of the master switch/
FI. Minimum cross section of the bath supply cable is 3x1,5 mm²
(length L = 1,8 m). In case of bathtubs equipped with an electric
water heater (2 kW) a supply cable with cross section of 3x2,5mm²
(length L = 2.0 m) should be used. Fixed electrical connection
of the bath should be prepared in zone I (the unit is located
under the tub), compensatory connection should be provided
additionally. A marked clamp
is mounted on the bath frame, to
which a compensating cable 4mm² should be connected.
Terminal made by the construction team should be in a form of a
permanent distributive damp-resistant socket (IP 65, at least 30
cm over the
fl
oor, in the area under the bathtub).When installing
a bathtub attention should be paid to the parts containing active
elements (except for items supplied with low safe voltage, i.e. not
exceeding 12 V) which must not be available for persons located
in bathtub.
The fact that bathtub is connected to the electricity must be noted
in the warranty card with signature and seal of the authorised
person, which determines validity of the guarantee.
02.03.1 Protected
Area
area 1
area 2
60 cm
area 2
60 cm
225 cm
area 0