background image

4

Wooden floor

Mortar floor

Mortar thickness of 50 mm or more

Special floor (stone finish)

A foundation with levels of strength listed above around the installation areas is required.

Plywood thickness of 30 mm or more (two 15 mm sheets joined together)

Power

To turn the power on, install the C-4 plug.
When the plug is changed due to a reason related to the customer, install a power plug that is suitable for the product.

Connecting to ground

To prevent accidents from occurring in the unlikely event of electrocution, and to improve noise resistance within control circuits, 
always install the ground designed for this product.

Do not connect the ground cable to any of the following:

Water pipes: any PVC pipes within the plumbing system will prevent a proper ground connection.

Gas pipes: there is a risk of an explosion or fire.

Telephone cables, lightning rods: there is a risk of a large current if there is a lightning strike.

Floor surface

Ensure that the material or finishing of the floor surface is waterproof or has a waterproof coating applied.

Always ensure that the floor surface is horizontally level.

Ensure that the floor surface is smooth and free from bumps around the attachment areas.

If the floor surface is tiled, cracks may occur when fastening the bolts during installation of the YUME ESPOIR main body. If this 
looks likely to happen, use the main body attachment diagram and template as a reference and change the material of the 
attachment area that is in contact with the floor to another such as plywood or mortar. 
Take care during installation as the entire base surface of the seat body is not in contact with the floor.

The following levels of strength are required for the floor surface.

Preventing water leakage

If this product is to be installed upstairs, ensure that the installation area has been coated with waterproof materials (waterproof 
finish, installation of a stainless steel pan or a water leakage sensor).

Fill the space between the installation area and pipe with caulking materials.

Precaution

 

Handling power plugs

Check the power plugs are free from dust, and insert the plug all the way to the base so that there is no rattle.
Dusty power plugs or improper connections can cause electrocution or fires.

Handling power cables

Do not subject power cables to excessive forces, modify, twist or bend them.
Power cables can become severed if they are placed under heavy objects or become trapped within tight areas, and can cause 
electrocution or fires.

Handling power outlets

Use power outlets for one appliance only, and always connect the ground terminal.
The use of multi-outlet extension cords can generate heat where the power outlet is divided, and can cause fires.

Handling circuit breakers and fuses

Always install a circuit breaker and fuse with the power outlet. Check that the white cable is neutral, and that the circuit breaker and fuse 
are connected properly to the neutral side of the power outlet. Installing circuit breakers off users incorrectly can cause electrocution.

Remove the power plug during inspections

Remove the power plug before conducting inspections or adjusting settings within the main body of YUME ESPOIR.
Coming into contact with electrical part while the power is connected may cause electrocution.

[Rated current]

230V Specifications

[Rated frequency]

50/60Hz

[Rated electricity consumption]

1.9/1.6A

Summary of Contents for YUME ESPOIR

Page 1: ...tomers must ask professional to install YUME ESPOIR Customers must not install YUME ESPOIR by themselves Customers must store these instructions in a safe place so as not to lose them The actual shape...

Page 2: ...model to model 2 Ensure that there is ample space surrounding the seat for extremely tall customers or if the surrounding area is used as a passageway Lowest position Highest position Wall Wall 295 2...

Page 3: ...ightly from model to model 2 Ensure that there is ample space surrounding the seat for extremely tall customers or if the surrounding area is used as a passageway 930 850 800 Height of neck cushion 1...

Page 4: ...base surface of the seat body is not in contact with the floor The following levels of strength are required for the floor surface Preventing water leakage If this product is to be installed upstairs...

Page 5: ...er cannot be controlled properly by the water taps which can cause problems including burns Ensure that the hot water pipes from water boilers are only run over a short distance so as to minimize resi...

Page 6: ...the main body cover In order to protect the basin and main body cover do not remove these until immediately before installation of the pipes Drain cap Hair catcher Basin body floor fixing screw set In...

Page 7: ...Backrest Backrest cover Cover set Base cover fixing screw set Base cover R Base cover L Seat body floor fixing screw set BP fixing screw set Legrest Areas that must not be used to carry the main body...

Page 8: ...s in the seat or toppling Precaution Always have at least two people to carry the main body and hold the basin when remove the bold Carrying the basin 1 Unpack the wood frame 2 Remove the maintenance...

Page 9: ...eat Attach neck cushion 2 Attach piping 7 Attach the base cover After attaching the base cover install base plate F to base plate H 8 Check operation 1 after assembling the seat 9 Attach backrest and...

Page 10: ...ay as above Precaution Do not pull the basin when attempting to move it Doing so may damage the floor Precaution Ensure that the power cable for installation is not trapped by the base Doing so may ca...

Page 11: ...se packing Drain hose clamp Drain hose Fasten Insert to this line Match the center width of drain hose clamp to the indent in the drain hose Firmly insert the drain hose packing until it hits the inne...

Page 12: ...sult in insufficient flow rate and faulty temperature regulation Take care not to damage or lose the O rings and packing Remove and clean any dirt trapped within the shower head Packing Aerator core A...

Page 13: ...Press firmly 2 Fasten M6 20 Plastic washer Base Base plate H If the power cable for installation is being installed from the water supply pipe and drain pipe area pass the cable through the bottom of...

Page 14: ...f the seat base and position at the plugging point If the power cable for installation is being installed from the floor under the seat Pass the power cable for installation from the floor and positio...

Page 15: ...or of the extension power cable sold separately to the seat connector 3 Pass the extension power cable sold separately through the hole in base plate U The fastening methods for base plate U is outlin...

Page 16: ...unctions Precaution Always attach the plastic washers If the washers are not attached water may leak through making it difficult to remove the screws Take care that the main power switch is not turned...

Page 17: ...or base plate and floor Is the cover or base plate vibrating or resonating while operating 4 Hold down pressing for one second or longer will make the unit beep the foot switch DN DOWN to raise the s...

Page 18: ...at and seat body with screws M8 25 8 1 Turn the main power switch on Press the right side symbol of the main power switch 2 Press the foot switch and check operation of the seat For operating procedur...

Page 19: ...de Seat side Head pillow underside The long edge faces seat side Attachment tool Hook Hook The short edge faces basin side Precaution Always conduct the following inspections to prevent accidents duri...

Page 20: ...ition to connect the main body power plug and power outlet This is not the location of the position to install the power cable Bolt anchor fixing position Recommended installation dimensions Distance...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...hi Chuo ku Osaka 542 0083 Japan TEL 81 6 6212 3523 FAX 81 6 6211 5745 TAKARA BELMONT CORPORATION MANUFACTURER TAKARACOMPANYEUROPEGmbH Berner Strasse 18 60437 Frankfurt am Main Germany TEL 49 69 506878...

Reviews: