TB8100 Service Kit User’s Manual
Working With Task Manager 193
Custom Actions
Opens the Custom Actions form, where you can define your own combination
of existing actions.
Custom Inputs
Opens the Custom Inputs form, where you can define your own combination
of existing inputs.
Move Up / Move
Down
Shift the selected item up or down one line. Use these buttons to rearrange the
order of tasks and comments in the task list.
Increase Indent /
Decrease Indent
Let you add or remove an indent from a selected task. Indents have no effect
on Task Manager processing; they help to make tasks easier to read and
understand. You can only indent tasks that are under a comment.
Enable / Disable
By default, tasks are enabled; when an input condition becomes true, Task
Manager processes the task. The Enable / Disable button lets you disable a task
so that it has no effect, or toggle it between enabled and disabled. A standard
base station can have up to 20 enabled tasks but up to 400 disabled ones.
Delete
The Delete button deletes the current task list item.
Adding a Task
To make full use of the base station’s capabilities, you need to add your own
tasks to the list that Task Manager processes. This enables Task Manager to
respond to events in a way that is tailored to your system. However, the set of
actions must be well thought out to operate in exactly the way you want. For
assistance, see
TN-1154-AN
Task Manager Programming Guide
.
Important:
It is possible to create tasks that undermine the base
station’s ability to operate properly. Make sure that the choices you
make are appropriate. Be particularly careful with powerful actions
such as
Reset base station
.
Important:
While Tait has carefully tested each input and each
action, it is not possible to test the enormous number of possible
combinations of inputs and actions. Thoroughly test any tasks you
add before commissioning the base station. If you are uncertain about anything,
refer to your supplier.
You can add a task anywhere in the task list. However, tasks in a channel profile
or a signalling profile folder will only be actioned if the current channel has that
profile assigned to it.
To define a task
1. Open a Task Manager form (see
“Accessing Task Manager” on page 191
).
2. If desired, click the folder you want the task to appear in.
3. Select
Task
in the Task list item area.
4. In the drop-down text box, select IF.
Alternatively, if you want the task to be processed when the input condition
goes from true to false, select IF NOT. For example, tasks with the input
Summary of Contents for TB8100
Page 1: ...TB8100 base station Service Kit User s Manual MBA 00010 08 Issue 8 December 2007...
Page 8: ...vi Contents Tait Electronics Limited December 2007...
Page 12: ...2 Introduction Tait Electronics Limited December 2007...
Page 26: ...16 Part A Introduction Tait Electronics Limited December 2007...
Page 28: ...18 Getting Started Tait Electronics Limited December 2007...
Page 38: ...28 Part B Getting Started Tait Electronics Limited December 2007...
Page 40: ...30 Basic Tasks Tait Electronics Limited December 2007...
Page 74: ...64 Part C Basic Tasks Tait Electronics Limited December 2007...
Page 76: ...66 Monitoring Tait Electronics Limited December 2007...
Page 88: ...78 Part D Monitoring Tait Electronics Limited December 2007...
Page 90: ...80 Configuring the Base Station Tait Electronics Limited December 2007...
Page 106: ...96 Part E Configuring the Base Station Tait Electronics Limited December 2007...
Page 108: ...98 Configuring Channels Tait Electronics Limited December 2007...
Page 154: ...144 Part F Configuring Channels Tait Electronics Limited December 2007...
Page 156: ...146 Alarms Tait Electronics Limited December 2007...
Page 176: ...166 Part G Alarms Tait Electronics Limited December 2007...
Page 178: ...168 Diagnosing Tait Electronics Limited December 2007...
Page 198: ...188 Part H Diagnosing Tait Electronics Limited December 2007...
Page 200: ...190 Task Manager Tait Electronics Limited December 2007...
Page 254: ...244 Tait General Software Licence Agreement Tait Electronics Limited December 2007...