Instruction and Operating Manual
TA-U1...U280
Misprints and technical changes reserved
48
7.0 Troubles
Separating protection equipment:
Internal: start at TA-U8: Prefuse F1 and F2 switched mode power supply
External: Mains fuse (look at Chapter 3.2.3 Drive data and Dimensions)
Non separating protection equipment:
To keep the device working correctly the following errors and operating states will be evaluated by the control board.
They will be displayed and stored.
These errors will disable the drive.
Chapter 7.1 gives detailed information about this.
F0 Motor overtemperature
F1 Overcurrent
F2 Drive overtemperature
F3 Undervoltage
F4 Overvoltage
F5 Rippel Current
F6 Position sensor U, V and W
F7 Speed sensor A and B
F8 Elektronic
F9 Short-Circuit IGBT
E1 External error at terminals
E2 No reducing circuit
E3 Fault brake feedback
The faults can be reseted by the terminals, the serial interface (RS 485 and RS 422), with the PG 4000. A fault reset is
only possible when the drive is locked, the motor stands still and all faults are disappeared.
Status indications:
0 Ready for run
1 Run (Enable)
C1 Drive temperature pre-warning
C2 Motor temperature pre-warning
C3 Max value out of range
C4 Safe Stop
C5 Drive Locked ref>0
C6 Powerstage disabled
C7 Actual speed > norming
C8 Parameterization fault