7.4 Replacing the fuses
(Fig 25)
WARNING
Replace the blown fuse with one
with the same amperage.
• Remove the squeegee lift pedal from the
squeegee lift arm.
• Unscrew the two bolts (1) that fasten the
external box (2) and remove it.
• Unscrew the two nuts (3) of the printed
circuit board cover (4) and remove it.
Replace Fuse (5) (Fig 26) Green 30A
• Reverse steps above to replace components
after fuse is replaced.
Fig 25
Fig 26
• Make sure that the solution tap is fully
closed. Refer to Fig 16.
• Unscrew the transparent filter cover (1) and
remove the filter (2).
• Clean the filter (2) in running water. If it is
blocked, replace it.
• Replace all the components in reverse order.
IMPORTANT
– All other servicing and repairs
should only be performed by a Powr-Flite
engineer or Authorized Service Agent.
IMPORTANT
– Should the machine fail to
operate please refer to the fault diagnosis
section (10) in the back of this instruction
manual. If the problem / remedy is not listed
please contact Powr-Flite Technical Service
Department.