Portbase User Guide
This protocol only works with the X-Console software. All data is encrypted by the SEED
method during communication.
For more information, visit the company website,
and refer to the
X-Console page under Products section.
J
Internal Modem (Only in PB-3010M)
Use the port as the modem port for PPP connection or console login
Baud Rate (Default: 9600)
Set communication speed. (150bps ~ 230Kbps)
Data Bits (Default: 8)
Set the number of bits in each character size. (7,8)
Parity (Default: None)
Set parity bit check scheme. (None, Even, Odd)
Stop Bits (Default: 1)
Set the number of stop bits. (1, 2)
Flow Control (Default: None)
Set the flow control scheme. (None, RTS, Xon)
Local Socket Port (Default: 4001~4004)
Set the socket number for the port.
Software makes use of this value for the network socket communication.
Port 1 4001, Port 2 4002, Port 3 4003, Port 4 4004 …
Device Type (Default: DataOnly)
Set the signal line check method for the device to be connected to the given serial port.
If the mode is set to DataOnly, only Txd, Rxd, and Gnd signal lines are used in inter-device
communication.
If the mode is set to Modem, all modem signals except RI(Ring Indicator) are asserted, tested,
and used in communication.
Alive Check Time (Default: 0 sec)