6.1.1 Display symbols
Symbol
Description
Explanation
Temp
Illustrates the current set temperature. The temperature
setpoint is set in 6 steps (from completely empty to filled
symbol).
Turn the SELECTION knob to choose temperature.
Press CONFIRM to save the setting.
Fan speed
Illustrates the current fan speed. The fan speed can be
set manually in 4 steps: Off, Low, Nom and High.
Turn the SELECTION knob to choose fan speed.
Press CONFIRM to save the setting.
A.Ventilation off.
1
B.Low ventilation: Can be used when leaving the
building for a longer period
C.Nominal ventilation: Will give required air change
under normal conditions.
D.Maximum ventilation: To increase the airflow if
necessary.
Service
Press CONFIRM to access the service menu.
Alarm
Press CONFIRM to access the alarm list.
1.
The fan can be set to OFF by activating MAN fan stop. See service menu description under functions.
Note:
It is not recommended to activate MAN fan stop (set fan to OFF) in standard households.
If MAN fan stop is activated, the unit should be provided with dampers in exhaust and fresh air ducts to
avoid cold draught and risk of condensation when the unit has been stopped.
SAVE VSR 300/500
Installation and Service
208115
10