SystemAir fantech ECHO 2800Xi Series Installation, Operation And Maintenance Manual Download Page 17

33

32

  Limited Warranty

•  The 

Heat recovery aluminum

 core has a lifetime warranty.

•  The 

Energy recovery 

core has a 3 year warranty.

•  Fantech commercial HRV/ERV's have a warranty that is limited to 3 years on all parts from the date of purchase, including parts replaced during 

this time period. If there is no proof of purchase available, the date associated with the serial number will be used for the beginning of the 
warranty period.

•  The motors found in all Fantech HRV/ERVs require no lubrication, and are factory balanced to prevent vibration and promote silent operation.

•  The limited warranty covers normal use. It does not apply to any defects, malfunctions or failures as a result of improper installation, abuse, 

mishandling,  misapplication, unfortunate occurrence or any other circumstances outside Fantech’s control.

•  Inappropriate installation or maintenance may result in the cancellation of the warranty.

•  Any unauthorized work will void of the warranty.

•  Fantech is not responsible for any incidental or consequential damages incurred in the use of the ventilation system.

•  Fantech is not responsible for providing an authorized service centre near the purchaser or in the general area.

•  Fantech reserves the right to supply refurbished parts as replacements.

•  Transportation, removal and installation fees are the responsibility of the purchaser.

•  The purchaser is responsible for adhering to all codes in effect in his area.

•  Fantech does not cover labor only parts.

*  This warranty is the exclusive and only warranty in effect relative to the ventilation system and all other warranties either expressed or implied 

are invalid.

8

1

2

3

4

9

5

6

7

10

11

BOM #

Description

ECHO H2800Xi

(95749)

ECHO E2800Xi

(95750)

1

R3G 355-PG60-25

414457

414457

2

Replacement core (3 cores per units)

414463 

414493

3

Filter,Merv8,H2800Xi,Rep.Kit

422991

422991

4

Filter,Merv13,H2800Xi,Rep.Kit

422992

422992

5

TFMR,480/240/208/120v-24V,75VA

412749

412749

6

Controlunit E283 WEB Small

209664

209664

7

Auto.fuse C32

413759

413759

8

Drain,Plug,3/4”,Threaded,Black

414476

414476

9

Pressigo Duo 2500

209651

209651

10

Terminal Block, 4 Pole, X.Large

413551

413551

11

Term.Block,TR Low Volt,Rev-2

414451

414451

Wiring Diagram

422871

422871

Installation  Manual

422974

422974

Parts list

Summary of Contents for fantech ECHO 2800Xi Series

Page 1: ...on of the National Building Code and or ASHRAE s Good Engineering Practices Fantech reserves the right to modify at any time and without notice any or all of its products features designs components a...

Page 2: ...d with BPM module only 21 o Extended running 23 o Fire alarm 26 o External switch 26 Alarm handling 27 Configuring BACnet MS TP port 1 29 Maintenance 31 Limited warranty 32 Parts list 33 The key to pr...

Page 3: ...clothes dryer kitchen exhaust hoods combustion venting central vacuum system These appliances may cause lint dust or grease to collect in the HRV ERV damaging the unit Location The HRV ERV must be pr...

Page 4: ...used to recirculate indoor air when ventilation is not required See the Recirculation section for more details If a BPM module accessory has been supplied with the unit it should be installed as per...

Page 5: ...ned and sealed to the ducts with proper duct sealant to minimize air leakage Dampers fitted to the ductwork connecting the unit to the outside weather hoods should be adequately insulated in order to...

Page 6: ...esponsibility of the installer to ensure all ductwork is sized and installed as designed to ensure the system will perform as intended The amount of air CFM that an HRV ERV will deliver is directly re...

Page 7: ...he return air side and can be accessed by opening the larger hinged access panel Pressure transducer modules Each module has two 2 pressure transducer The first pressure transducer on the PTE module m...

Page 8: ...nting holes 8 Connection block 9 Connection to yellow cable 10 Connection to orange cable 11 Connection to red cable 12 Connection to brown cable 13 Connection to black cable Supplied Cable 10 12 11 1...

Page 9: ...hanges from stopped to starting up 2 The digital outputs for the fresh air damper and the exhaust air damper are activated 3 The exhaust air fan and the supply air fan will start after a preset time N...

Page 10: ...e and time follow the steps below Time settings schedule 1 Time settings Go to Time settings by using the UP DOWN arrow buttons Select by pressing the RIGHT arrow button Temperature Air Control Time s...

Page 11: ...be done when ventilation is not required during a certain period but air circulation is desired Recirculation units equipped with the BPM module only To have the recirculation mode controlled by a dig...

Page 12: ...ow button Manual Auto Settings Configuration Access rights Once the input has been set the recirculation mode can be configured 3 Recirculation Using the UP DOWN arrow buttons locate the use extra tim...

Page 13: ...cess the fields and set values Extended running 0 min Set the time value for extended running to remain active once the extended running input goes from on to off Time in ext running 0 min This field...

Page 14: ...ing the UP DOWN arrow buttons Select by pressing the RIGHT arrow button AI DI UI AO Alarm handling The unit controller comes with preprogrammed alarms to ensure it functions properly and to help troub...

Page 15: ...isplay Follow the steps below to handle active alarms 1 Access the alarm log Press the alarm button to access the alarm log when the red LED is flashing to indicate that an alarm has been triggered On...

Page 16: ...n a large sink bathtub or shower 5 Pour clean tap water through the face of the core facing upward until it runs clear Ensure the entire surface is rinsed 6 Rotate the core so that its other air inlet...

Page 17: ...ges incurred in the use of the ventilation system Fantech is not responsible for providing an authorized service centre near the purchaser or in the general area Fantech reserves the right to supply r...

Page 18: ...35 34 Notes Notes...

Page 19: ...Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech...

Reviews: