![Sys Tec Electronic USB-CANmodul System Manual Download Page 58](http://html1.mh-extra.com/html/sys-tec-electronic/usb-canmodul/usb-canmodul_system-manual_1421546058.webp)
USB-CANmodul
56
SYS TEC electronic GmbH 2001 L-487e_6
USBCAN_ERRCMD_NOTEQU
Value: 0x40
Description:
This error code occurs during communication between the PC
and a USB-CANmodul. The PC sends a command to the USB-
CANmodul, then the module executes the command and returns
a response to the PC. This error message returns if the answer
does not correspond to the command.
USBCAN_ERRCMD_REGTST
Value: 0x41
Description:
The software tests the CAN controller on the USB-CANmodul
when the CAN interface is initialized. Several registers of the
CAN controller are checked. This error message returns if an
error appears during this register test.
USBCAN_ERRCMD_ILLCMD
Value: 0x42
Description:
This error message returns if the USB-CANmodul receives a
non-defined command. This error shows a version conflict
between the firmware in the USB-CANmodul and the
USBCAN32.DLL.